Rev. May 2001
GraviMaster-FGB-M05 (S)
Page 9
Gravimetric
Blender
2.7.2 Recipe to weight calculation
After a start-command the controller will calculate the requested weights of all components
of the selected recipe.
A recipe can be defi ned in two ways: ‘Standard’ and ‘Percentage’. These methods can
be
defi ned in the recipe choosing menu (F1)
‘recipes / edit recipes’
. The methods
‘Standard’ end ‘Percentage’ defi ne the relation of the components (Regrind, Natural and
Additive) in a recipe.
2.7.2.1 Method Standard
The different components are defi ned as follows:
Regrind
:
Percentage of the batch weight
Natural
:
Relation between other naturals
Additive
:
Percentage of the totals of all naturals
Example
Batchweight
2000.0
gr.
Regrind
20.0%
Natural
1
4
Natural
2
1
Additive
5.0%
Regrind
: 20.0%
of
2000.0
gr.
400.0
Naturals
:
na additive = 80.0%
na (0,05 * naturals) = 80.0%
naturals = 80.0/1.05 = 76.2%
natural 1 = 4/5 * 76.2 = 61.0%
1220.0
natural 2 = 1/5 * 76.2 = 15.2%
304.0
Additive
:
80.0 - 61.0 - 15.2 = 3,8%
76.0
TOTAL 2000.0
Содержание FGB-M05
Страница 1: ...MANUAL GraviMaster FGB M05 S Gravimetric Blender Serial No ISO 08 01 02 064 GB 986731 Rev May 2001...
Страница 17: ...Rev May 2001 GraviMaster FGB M05 S Page 16 Gravimetric Blender 2 9 EQ Net Certificate...
Страница 18: ...Rev May 2001 GraviMaster FGB M05 S Page 17 Gravimetric Blender 2 10 ISO Certificat...
Страница 50: ...Rev May 2001 GraviMaster FGB M05 S Page 49 Gravimetric Blender 7 5 Electrical diagrams...
Страница 51: ...Rev May 2001 GraviMaster FGB M05 S Page 50 Gravimetric Blender...
Страница 52: ...Rev May 2001 GraviMaster FGB M05 S Page 51 Gravimetric Blender...