Rev. May 2001
GraviMaster-FGB-M05 (S)
Page 33
Gravimetric
Blender
PUBLIC
PARAMETERS
Parameter Description
Init
AlarmReport
Indicates if alarm-reports must be printed.
No
*)
ProductionReport
Indicates if production-reports must be printed.
No
*)
If so the parameter interval-time must be given also.
Interval
Pauze (time) before printing the next production-report. 01:00.00
BatchReport
Indicates if batch-reports must be printed.
No
*)
ProductionMode
Actual production-mode. There are three possible
CONTINUE
modes; CONTINUE, WEIGHT and ALARM_
WEIGHT. If the mode WEIGHT os ALARM_
WEIGHT has been selected the parameter production
Weight must also be given.
ProductionWeight
The FGB stops his production when the production
100 [Kg]
Weight is reached. (productionMode must be
WEIGHT
or
ALARM_WEIGHT).
DispenseMode
Actual dispense-mode. There are three possible
GRAVIMETRIC
modes; GRAVIMETRIC, VOLUMETRIC and
COMBINATION. If the mode COMBINATION is
chosen the parameter combinationRatio must be given.
CombinationRatio
Relation between the volumetric and gravimetric
3
dispenses. (one gravimetric dispense and x
volumetric
dispenses).
MixMode
Actual mixermode. There are four possible modes;
PULSE
ON, OFF, NORMAL and PULSE. In normal-mode
the parameter mixerOnTime must be given. In the
mode pulse the parameters mixerPulseOnTime and
mixerPulseOffTime must be given.
MixerOnTime
Time the mixer is activated after the material is
10 [s]
dumped out of the weighbin.
MixerPulseOnTime
Time the mixer is activated in pulse-mode.
5 [s]
MixerPulseOffTime
Time the mixer is not activated in pulse-mode.
15 [s]
AdditiveToRegrind
Percentage additive to regrind which must be added. 0 [%]
Percentage 1/2
AdditiveToRegrind
Hoppernumber in which the additive is.
Hopper 5
Hopper 1/2
WeighbinDumpTime
Time the weighbinvalve is activated (dumping of
4 [s] 0,5 kg unit
material into the mixerchamber).
6 [s] 1,2,5 and
25 kg unit
LevelControlWaitTime
Time between the full signal of the mixerchamber
8 [s]
sensor and opening the mixerchamber-valve.
LevelControlDumpTime Time between the free signal of the mixerchamber
sensor and closing the mixerchamber-valve.
1 [s]
*)
No = [ ], Yes = [X]
Содержание FGB-M05
Страница 1: ...MANUAL GraviMaster FGB M05 S Gravimetric Blender Serial No ISO 08 01 02 064 GB 986731 Rev May 2001...
Страница 17: ...Rev May 2001 GraviMaster FGB M05 S Page 16 Gravimetric Blender 2 9 EQ Net Certificate...
Страница 18: ...Rev May 2001 GraviMaster FGB M05 S Page 17 Gravimetric Blender 2 10 ISO Certificat...
Страница 50: ...Rev May 2001 GraviMaster FGB M05 S Page 49 Gravimetric Blender 7 5 Electrical diagrams...
Страница 51: ...Rev May 2001 GraviMaster FGB M05 S Page 50 Gravimetric Blender...
Страница 52: ...Rev May 2001 GraviMaster FGB M05 S Page 51 Gravimetric Blender...