background image

 

USER 

 

MANUAL

 

MODEL 1173R

 

IP Network
Camera Extender

 

SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007

 

Part# 07M1173-UM
Doc# 03333U2-003
Rev. A
Revised 5/21/08

 

An ISO-9001Certified

Company

Содержание 1173R

Страница 1: ...USER MANUAL MODEL 1173R IP Network Camera Extender SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1173 UM Doc 03333U2 003 Rev A Revised 5 21 08 An ISO 9001Certified Company ...

Страница 2: ... the 10 100Base T Ethernet Interface 11 3 3 Connecting Power 11 4 0 Configuration 12 4 1 Configuring the hardware DIP switches 12 4 2 Configuring DIP Switch S2 13 Switch S2 1 Reserved 14 Switches S2 2 and S2 3 Data Rate 14 5 0 Operation 15 5 1 Power Up 15 5 2 Front Panel LED Status Monitors 16 A Specifications 17 A 1 LAN Connection 17 A 2 Transmission Line 17 A 3 Line Rate and Distance 17 A 4 Surg...

Страница 3: ...3 C Model 1173R Series Interface Pin Assignment 19 C 1 10 100Base T Interface 19 RJ 45 19 C 2 Line Interface 19 RJ 45 19 Terminal Block 19 D Distance Chart Based on 24 AWG 0 5 MM 20 ...

Страница 4: ...y damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms ...

Страница 5: ...plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 1 3 CE DECLARATION OF CONFORMITY We certify that the apparatus described above conforms to the require ments of Council Directive 2004 108 EC on the approximation of the laws of the member states relating to electromagnetic compatibility and Council Directive 2006 95...

Страница 6: ...s are present in WAN ports regardless of whether power to the unit is ON or OFF To avoid electric shock use caution when near WAN ports When detaching the cables detach the end away from the device first Do not work on the system or connect or disconnect cables during periods of lightning activity In accordance with the requirements of council direc tive 2002 96 EC on Waste of Electrical and Electr...

Страница 7: ... Power Link and Camera s Ethernet Link Activity Surge suppression up to 20 kA 8 20 μs Made in the USA 2 2 DESCRIPTION The Patton Electronics Model 1173R IP Network Camera Extender pro vides high speed Ethernet connections between an Ethernet LAN or remote PC to a 10 100Base T IP camera Operating in pairs one Model 1173R is configured as the L LAN unit located at one end of the LAN extension and the...

Страница 8: ... 1 Connecting the Twisted Pair Line Interface on page 9 Note See Figure 2 for the standalone unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting the 10 100Base T Ethernet Interface on page 11 3 Connect the power plug refer to section 3 3 Connecting Power on page 11 The Interconnecting cables shall be acceptable for external use and shall be rated for the...

Страница 9: ...a link by being powered on or by having its power reset 1 To function properly the two Model 1173Rs must be connected together using twisted pair unconditioned dry metal wire between The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem perature flammability and mechanical serviceability Twisted...

Страница 10: ...s wired for a two wire interface The signal pin relationship is shown in Figure 3 Figure 3 Model 1173R RJ 45 twisted pair line interface The terminal block connector on the Model 1173R s twisted pair interface is polarity insensitive and is wired for a two wire interface The signal pin relationships is shown in Figure 4 Figure 4 Model 1173R Terminal Block twisted pair line interface 1 no connectio...

Страница 11: ... is necessary for the power supply See Appendix B for domestic and international power supply and cord options DC power supplied via the power supply jack to the 1173R must meet the follow ing requirements DC power supplied must be regulated 5VDC 5 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions The Interconnecting cables shall be acceptable fo...

Страница 12: ...switch locations and explains the different configurations 4 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove the protective cover located on the underside of the Model 1173R see Figure 6 Figure 6 Removing protective cover Figure 7 on page 13 shows the orientation of the DIP switches in the On and Off positions ...

Страница 13: ...ough S2 8 Detailed descriptions of each switch follow the table Table 1 S2 Summary Position Description S2 1 Reserved S2 2 Line Rate S2 3 Line Rate S2 4 Ethernet configuration S2 5 Ethernet configuration S2 6 Ethernet configuration S2 7 Ethernet Shutdown S2 8 Remote Configuration ON OFF 1 2 3 4 ON Push toggle up for ON position Switch toggle Push toggle down for OFF position 1 2 3 4 ON S2 S2 5 6 7 8 5...

Страница 14: ... S2 6 to configure Ethernet settings Table 2 Ethernet Auto Sense Selection Chart S2 1 Setting ON Reserved OFF Reserved Table 3 Rates Selection Chart S2 2 S2 3 Line Rates DS US ON ON 50 Mbps 2 Mbps ON OFF 16 Mbps 2 Mbps OFF OFF 4 Mbps 1 Mbps Table 4 Ethernet configurations S2 4 S2 5 S2 6 Ethernet Configurations ON ON ON Auto Negotiate ON ON OFF 100Mb Full Duplex ON OFF ON 100Mb Half Duplex ON OFF OFF ...

Страница 15: ...ting to determine its Ethernet operating mode and Ethernet Shutdown mode configuration The S2 8 switch does not affect the data rate The data rate will always follow the L configuration 5 0 OPERATION Once the Model 1173Rs are properly installed they should operate transparently No user settings required This section describes reading the LED status monitors 5 1 POWER UP Before applying power to the ...

Страница 16: ... Table 7 Front panel LED description LED Description Power Solid GREEN to indicate the unit is powered on Link Solid GREEN ON to indicate that the end to end link between the Model 1173Rs is established The Link LED is OFF when the link is down Camera Solid GREEN indicates that 10 100Base T Ethernet link has been established Flashes to indicate activity Camera LED Link LED Power LED C a m e r a L ...

Страница 17: ...ns See Appendix D on page 20 for details A 4 SURGE SUPPRESSOR SIDACTOR with maximum current surge 20 kA 8 20 μs A 5 LED STATUS INDICATORS Power Green Link Green Camera Link Green Activity Flashing Green A 6 POWER SUPPLY External AC and DC options AC 120 VAC 220 VAC and UI 120 240 VAC DC 12 VDC 24 VDC and 48 VDC Power consumption 450 mA at 5 VDC A 7 TEMPERATURE RANGE 10 to 70 C A 8 HUMIDITY Standar...

Страница 18: ...ra Extender Kit 10 to 70 C conformal coated humidity 85 condensing from 10 to 35 C UI 07M1173 UM User Manual Power Supplies 08055DCUI 08055 120 5 1 100 240VAC 5V reg DC 2A Universal Input Adapter 120 VAC 5V reg DC 1A Input Adapter 12V PSM 12 VDC Input Adapter 24V PSM 24 VDC Input Adapter 48V PSM 48 VDC Input Adapter Power Cords 0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK Un...

Страница 19: ...n 6 RX Pins 4 5 7 8 no connection C 2 LINE INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection Terminal Block Figure 1 Model 1173R Terminal Block twisted pair line interface RING TIP Camera Link Power M o d e l 1 1 7 3 I P N e t w o r k C a m e r a E x t e n d e r Link Power 5V 0 6A IP Network Camera C L ...

Страница 20: ...ing on the environment and type gauge of wire used Note DS downstream US upstream Copyright 2008 Patton Electronics Company All Rights Reserved Line Rate DS US Distance in feet km Throughput at Max Distance DS US 50 Mbps 2 Mbps 2 000 0 61 km 48 2 16 Mbps 2 Mbps 4 000 1 22 km 15 2 4 Mbps 1 Mbps 6 000 1 82 km 3 75 1 ...