1. After the microscope has been used for observation of a specimen
containing bacteria, clean all parts coming in contact with the specimen
to prevent infection.
Be sure to remove the specimen before moving this product.
In case the specimen is damaged by erroneous operation, it is
important to clean all surfaces that may have come in contact with the
specimen.
2. To avoid potential shock hazards and burns when replacing LED, turn
the microscope’s main switch to OFF position and disconnect power
cord from wall outlet in advance. Whenever you replace bulb during use
or right after use, allow lamp socket and bulb to cool before touching
3. Install microscope on a sturdy, level table or bench and avoid any blockage of air vents on the bottom side of the
base.
2. Do not place microscope on a flexible surface, as this could result in blocking the air vents and cause
overheating/fire.
4. Always use the power cord provided by LABOMED. If the proper power cord is not used, product safety
performance cannot be warranted.
5 When installing the microscope, route the power cord away from the microscope frame. Should the power cord
come in contact with the microscopes base, the power cord could short circuit.
6 Always ensure that the grounding terminal of the microscope and that of the wall outlet are properly connected. If
the equipment is not grounded, LABOMED can not warrant the electrical safety performance of the equipment.
7 Never allow metallic objects to penetrate the air vents of the microscope frame as this could result in user injury and
equipment damage.
8 After operation of microscope, be sure to disconnect power cord from connector on the microscope or from the wall
power outlet.
¡
¡
Applicable LED replacement: LED P/N 9135000-901
Fig. 1
Safety Symbols
Symbol
Explanation
Indicates that the surface has a tendency to heat up and should not be touched unless
system has completely cooled down.
Before use, carefully read the instruction manual. Improper use could result in
injury to the user and/or damage to the equipment.
Indicates that the main switch is ON.
Warning against risk of electric shock.
Indicates that the main switch is OFF.
The following symbols are found on the microscope. For optimal use, it is recommended that users understand
these symbols and always use the equipment as prescribed.
|
!
Lx 100/200
2
SAFETY INFORMATION
2
Issue 1.0
5030000-795 User Manual Lx-100/200 Printed on July,2013