LID-3300IP Ice Detector
D80186JE-3
Installation and Operating Instructions
Copyright ©
2016 Labkotec Oy
23/37
6
TECHNICAL SPECIFICATION
LID-3300IP Ice Detector Control Unit
Enclosure
Dimensions: 125 x 175 x 75 mm (h x w x d)
Weight: 800 g.
Material: Polycarbonate
Degree of protection: IP 65
Operating environment
Temperature:-30 ºC
…+55 ºC
Max. altitude above sea level: 3000 m
Power supply
230 VAC±10%, 50/60 Hz. Max fuse size in the supply line is 20 A.
Power consumption
Normally 7 VA. Max 350 W during sensor heating
Fuses
F804 50 mAT, F800 and F801 3.15 AT, IEC 127 5 x 20 mm
Analog outputs (source)
2 pcs, active current output 4-20 mA to max. 1 k
Ω load (for Ice signal and tem-
perature). Connector numbers 11
– 14.
If analog outputs are used, please use galvanic isolation.
Relay outputs
2 pcs (Ice alarm and fault), potential free relay output.
Connector numbers 5
– 10.
U
max
30 V, I
max
1 A.
Front panel
LED indication for Power, Ice Alarm, Heating and Fault.
Test button to simulate Ice Alarm.
Serial outputs
(Only either of the inter-
faces can be used at a
time)
RS-232 serial output for configuration and automatic reading
Optical fibre serial output for configuration and automatic reading (optional, re-
quires an additional RS2O Converter module):
RS2O Converter module is CLASS 1 LASER PRODUCT
RS2O Converter module transmitter: HFBR-1522ETX
RS2O Converter module receiver: HFBR-2522ETZ
Connector for optical fiber in RS2O converter module: HFBR4531 or equivalent
Cable type: POF (1 mm) up to 45m
Web server
Integrated Web server and web based user interface for remote access to Ice
Detector via Internet. Standard RJ-45 connector. Network settings can be con-
figured via RS-232.
Default IP address: 192.168.1.88.
Electrical Safety (LVD)
EN/IEC 61010-1, Class I, CAT II
UL 61010-1
CAN/CSA-C22.2 NO. 61010-1-04+GI1
CAN/CSA-C22.2 NO. 61010-2-010-04
EMC
EN/IEC 61000-6-4 + A1 (Emission)
EN/IEC 61000-6-2 (Immunity)
Functional Safety
Hardware of LID-3300IP ice detector system fullfills the requirements of PL b
according to ISO 13849-1.
Approvals
US+Canada NRTL-Certificate
In the USA and Canada the product is intended to be installed with
a 230 Vac wind turbine power system only
Component certificate according to GL Rules and Guidelines
– IV
Industrial Services
– Part 1 – “Guideline for the Certification of Wind
Turbines” Edition 2010. Certificate No. CC-GL-013A-2014.