LID-3300IP Ice Detector
D80186JE-3
Installation and Operating Instructions
Copyright ©
2016 Labkotec Oy
26/37
Format 2: LID-3210 format
Command
RSFORMAT 2
sets the output format identical to what was used in
LID-3210 Ice Detector.
The output format consists of the following information:
The different fields are delimited with a space character. Fail and Mode
characters have no space between them. Temperature values start with
zeros and have a
‘+‘ or ‘-‘ sign in front of the value. Ice signal amplitude
has an asterisk (*) in front of the value.
-
Example (one temperature sensor):
0F +015.0 *068
No fail, Mode: detecting, ice sensed, heating on, Sensor
temperature 15.0°C, ice signal amplitude 68.
-
Example (two temperature sensors):
8F -005.0 -005.0 *048
Heating failed, Mode: detecting, ice sensed, Sensor temperature -
5.0°C, ambient temperature -5.0°C, ice signal amplitude 48.
Fail and Mode Characters
The reason for failure can be interpreted from the Fail character as
follows:
Fail character
Meaning
Heating
EEPROM
Temperature
sensors
Ice sensing
0
OK
OK
OK
OK
1
OK
OK
OK
Failed
2
OK
OK
Failed
OK
3
OK
OK
Failed
Failed
4
OK
Failed
OK
OK
5
OK
Failed
OK
Failed
6
OK
Failed
Failed
OK
7
OK
Failed
Failed
Failed
8
Failed
OK
OK
OK
9
Failed
OK
OK
Failed
A
Failed
OK
Failed
OK
B
Failed
OK
Failed
Failed
C
Failed
Failed
OK
OK
D
Failed
Failed
OK
Failed
E
Failed
Failed
Failed
OK
F
Failed
Failed
Failed
Failed
Fail
Mode
Sensor temperature with
sign mark (+/-) and leading
zeros
Ambient temperature
with sign mark (+/-) and
leading zeros
Ice signal amplitude
with leading zeros