LID-3300IP Ice Detector
D80186JE-3
Installation and Operating Instructions
Copyright ©
2016 Labkotec Oy
32/37
22
RSFORMAT
<x>
Set RS-232
communication format
0 = variable length, 1
= constant length, 2 =
LID-3210
RSFORMAT 1 yes
23
RSFORMAT
Read RS-232
communication format
None
RSFORMAT
yes
24
ST2LOCK
Lock / unlock
updating the value of
ambient temperature
(T2) during heating
and cooling phases.
0 = unlock T2 update
1 = lock T2 update
ST2LOCK 0
ST2LOCK 1
yes
25
RT2LOCK
Read ambient
temperature (T2) lock
state
None
RT2LOCK
yes
26
SDNS<x>< >
<aaa.bbb.ccc.
ddd>
Set Domain Name
Server ip-address
< x> = 1
– 3
< > = space
1 = primary DNS
2 = 1st alt. DNS
3 = 2nd alt. DNS
aaa.bbb.ccc.ddd =
DNS IP-address
SDNS1 8.8.8.8
yes
27
SNTP<x>< >
<abcdefghijkl>
Set network time
server name string
<x> = 1
– 3
< > = space
1 = primary NTP
2 = 1st alt. NTP
3 = 2nd alt. NTP
abcdefghijkl =
server name string
SNTP1
time1.google.c
om
yes
28
STZN <x>
Set local time zone
related to UTC
(Universal Time
Coordinated). Needed
only when SNTP-
client is in use.
<x> = integer
-
12…+12
STZN 2
yes
29
SNWT <x>
Set SNTP- client
ON/OFF
< x> = 0 -> OFF
< x> = 1 -> ON
SNWT 1
yes
30
SCLOCK< >
<DD>.<MM>.
<YY><><hh>:
<mm>:<ss>
Set system time
< > = space
<DD> = date 0-31
<MM> = months 0-12
<YY> = years 0-99
<hh> = hours 0-23
<mm> = minutes 0-59
<ss> = seconds 0 -59
SCLOCK
09.06.14
10:05:00
yes
31
RLOG <x>
Print event log
segment to RS-232
terminal.
<x> = 1 - 5 log seg-
ment to print.
1 = Alarms
2 = Faults
3 = User settings
4 = General events
5 = All
RLOG 2
32
FTEST
Test manually fault
relay de-energisation
none
FTEST
yes