Product icons

Icons in these instructions for use

The icons described below can be found in these instructions for use, on the pigmentation device, AC adapter, needle cartridge and their packaging.  The icons 
provide information about the correct and safe use of the product.

Icon

Meaning

Reference to the product’s instructions for use

Contact details for the product manufacturer

Product manufacturing date

The product meets the requirements of the EMC Directive 2014/30/EU 
and the Low Voltage Directive 2014/35/EU
The product meets the requirements of standard 
DIN EN 61140 protection class II

The product may only be used indoors

The product complies with WEEE Directive 2012/19/EU for waste 
electrical and electronic equipment
Indicates the polarity of the output connector on the AC adapter 
connector cable. The centre (also called tip) is positive (+) and the 
cylinder (ring) negative (−)

Voluntary testing of the product / production site according to TÜV 
Süd’s test and certification regulations in Germany

The product complies with the requirements of Article 20 of the 
Product Safety Act (ProdSG)

Store the product in a dry place

Product is unusable if the packaging is damaged

The housing offers protection against coarse dust and drops of water

Device meets the requirements of the RoHS 2 Directive

Icon

Meaning

Observe the temperature limit

Observe the humidity limit

Do not reuse the product

Do not resterilise the product

Hazards to people and the environment from biological substances or 
organisms

Expiry date / Product can be used until date:

Sterilised with ethylene oxide

No reproducible germs such as microorganisms and viruses

Warning against cuts or needle-prick injuries

Internationally recognised, voluntary labelling of packaging and 
materials used in them for recycling

Catalogue number, order number

Batch number as reference number for unique identification

Содержание Mini

Страница 1: ...LaBina Mini pigmentation device Instructions for use EN...

Страница 2: ...eferred to as cosmetic tattoos in which microscopically fine ink pigments are injected into the top layers of skin using a special needle The inks fade after 2 5 years depending on the condition of th...

Страница 3: ...s for use transport and storage must be complied with When using the pigmentation device care must be taken that the needle cartridges used are equipped with an internal membrane which reliably ensure...

Страница 4: ...d tip is positive and the cylinder ring negative Voluntary testing of the product production site according to T V S d s test and certification regulations in Germany The product complies with the req...

Страница 5: ...he instructions in these instructions for use Icon Meaning Observe safety instructions and their measures It is always used where there are risks for the user or the device if the safety instructions...

Страница 6: ...ons for use GebrAnw LaBina mini Control unit AC adapter SK05T 1900 12 volts DC Mains connection voltage 90 264 volts AC Dimensions 100 240 Volt AC Abmessungen 72 x 72 x 35 mm Handpiece Handpiece drive...

Страница 7: ...7 7 AC adapter Handpiece Handpiece holder Control unit Scope of delivery...

Страница 8: ...nnect the power supply in the event of a malfunction Do not use any damaged equipment or accessories Damage to cables or the equipment significantly increases the risk of electric shock Ensure that al...

Страница 9: ...l Plug the foot switch connector into the green foot pedal connection socket The handpiece is activated turned on and deactivated turned off by pressing the foot pedal CAUTION Tripping hazard due to c...

Страница 10: ...the power supply Keys Always start the handpiece with the needle car tridge inserted to prevent damage to the hand piece Start Stop key Pressing the Start Stop key activates the handpiece after a sho...

Страница 11: ...11 11...

Страница 12: ...m fine 0 25 mm 08 basic 0 30 mm 10 bold 0 35 mm 12 slim 0 18 mm 06 fine 0 25 mm 08 basic 0 30 mm 10 fat 0 40 mm 14 basic 0 30 mm 10 5 mm 5 mm 5 mm 5 mm long long long long 2 5 mm 2 5 mm 2 mm 2 5 mm me...

Страница 13: ...h Head Grind 1 long slim 06 18 1 RLLT 06 0 18 mm 1 Round Liner Long Taper Polished Bug Pin 5 mm 3 long slim 06 18 3 RLLT 06 0 18 mm 3 Round Liner Long Taper Polished Bug Pin 5 mm 1 long fine 08 25 1 R...

Страница 14: ...ting a needle cartridge into the handpiece Applying slight pressure insert the dark green needle cartridge into the handpiece opening as far as it will go The cartridge is now securely in place in the...

Страница 15: ...due to excessive working speed w If the working speed is too high the risk of additional skin injuries increases When choosing the working speed consider the condition of the customer s skin and the t...

Страница 16: ...shaft of the needle cartridge DANGER Transmission of diseases No more treatments using a previously used needle cartridge The use of contaminated needles can lead to the transmission of diseases LaBi...

Страница 17: ...be cleaned and if these products are used incorrectly the surfaces may be damaged Never clean the control unit handpiece or AC adapter in an autoclave or ultrasonic bath Use a mild detergent for sens...

Страница 18: ...surfaces in the treatment room such as the treatment couch shelves floors and walls should be easy to clean and free of dust or impurities Smoking eating and drinking should be avoided in treatment r...

Страница 19: ...persons with acute cardiovascular problems or epilepsy In principle it is no problem to perform a treatment in case of HIV or hepatitis however the customer is asked to inform the practitioner before...

Страница 20: ...days before the treatment is appropriate The customer should avoid household tasks such as cleaning garages and cellars where contamination with dirt and germs is possible With all treatments the fres...

Страница 21: ...edemas may occur for up to six days Skin irritations usually disappear within two days Skin scab and peeling These reactions may last for up to a week Rare reactions Formation of herpes simplex virus...

Страница 22: ...ective in combating viruses 4 If the skin is damaged gently rinse the area of the needle prick injury using an antiseptic for skin that is effective in combating viruses 5 In the case of puncture woun...

Страница 23: ...d after consultation with your distributor please send the pigmentation device directly to the manufacturer After the manufacturer has received the defective device they will be happy to send you an e...

Страница 24: ...monisierungsrechtsvorschriften festgelegt sind complies with the essential requirements of the following harmonization Iegislation 2014 30 EU EMV Richtlinie 2014 35 EU Niederspannungsrichtlinie 2011 6...

Страница 25: ...25 25 Notes...

Страница 26: ...49 5691 89530 Info LaBina24 de www PermanentLine de LaBina24de LaBina24_de www LaBina24 de LaBina ist eine Handelsmarke von PERMANENT Line GmbH Co KG Mengeringh user Stra e 15 34454 Bad Arolsen German...

Отзывы:

Похожие инструкции для Mini