34
OA-PRESENCE T SENSOR WIRING
ETERNA 90 OPERATOR ET-LOGIC-B TERMINAL
Correspondence between the sensor cables and the terminal board of the ETERNA 90 operator ET-LOGIC-B control
1. RED
(+)
Power supply
TERMINAL 22 (+)
2. GREEN
(-)
Power supply
TERMINAL 21 (-)
3. BLUE + Opto NPN (sensor 1 safety)
BLUE +
Opto NPN (sensor 2 safety)
TERMINAL 8
E.O.1 Opening safety sensor 1
TERMINAL 9
E.O.2 Opening safety sensor 2
4. WHITE - COM
(sensor 1 safety)
WHITE - COM
(sensor 2 safety)
TERMINAL 7 COMMON
7. BROWN
(+)
Test
TERMINAL 20 TEST (+)
8. ORANGE
(-)
Test
TERMINAL 21 (-)
OA-PRESENCE T DIP SWITCH SETTINGS
DIP 10 = ON
Test input Low
For information about the adjustments and the other sensor
functional settings, please refer to the instructions supplied with
the OA-PRESENCE T sensor.
ET-DSEL PROGRAMMER FUNCTIONAL SETTINGS
F14 (S07) = ON
If the safety sensor is installed on E.O.1
F15 (S08) = ON
If the safety sensor is installed on E.O.2
F17 (S10) = ON
Opening safety sensor test enabled
F18 (S11) = OFF
LOW level test
The safety sensor operation test is carried out at the beginning of each door opening and closing cycle.
Should the sensor fail to properly respond to the test request by the operator control unit, the control unit buzzer will beep and the leaf
motion speed will be slow throughout the entire stroke.
17.3) OA-PRESENCE T SENSOR
Application as opening side safety sensor