53
25)
MAINTENANCE
To enter, type the 10-character technical password (for more information, refer to “Password management” paragraph).
This section is only accessed to reset any error existing in the event memory and the partial counter of the door opening/closing cycles and to
cancel the initial set-up previously saved during installation.
The event memory and partial counter reset must be performed by specialized personnel only during routine maintenance, after performing
all system operation checks.
The buttons in this section are used as follows:
Ÿ
The v button allows to move forward in the next selection.
Ÿ
The ^
F2
button allows to return to the previous selection.
Ÿ
F1
(OK) button allows to confirm the selected operation.
Ÿ
The
F3
button is only used if the ET-DSEL digital programmer is connected to two operators for the management of two automatic doors
and the symbol in the top right section of the display indicates 1 if the reset operations refer to operator 1, or 2 if they refer to operator 2.
Every touch on
F3
button allows to switch from 1 to 2 and vice versa.
If the ET-DSEL programmer only manages a single operator the symbol "1" is displayed at the top right.
- CANCEL SET-UP
The GENERAL RESET returns the electronic control unit to the factory settings.
25.1) PLUG and PLAY
The PLUG and PLAY option allows you to configure the desired functions and parameters of the automatic door directly in the factory, before
sending the automation to the site for installation.
To adjust the functions and parameters, refer to the paragraph "Functions and Settings".
After selecting the desired functions, enter in the "SERVICE" section of digital programmer ET-DSEL described in this paragraph, select the
"PLUG and PLAY" option with the arrow and press the F1 (OK) button.
The buzzer of the electronic control unit emits 5 beeps.
Disconnect the power to the automation.
Once the automatic door has been installed, to perform the initial set-up follow the steps below:
a)
MOVE THE DOOR TO THE CLOSING POSITION.
THE AUTOMATION WILL DETECT AUTOMATICALLY THE CORRECT DIRECTION OF OPENNG DURING THE SET-UP CYCLE.
b)
Power the ETERNA 90 automation by mains voltage, the control unit buzzer emits 5 short beeps.
c)
Press the PS1 button (START) on the electronic control unit to start the initial set-up cycle, or alternatively, enter the "SET-UP" section
of the general programming menu and select the "PARTIAL" option from the set-up mode.
d)
During the set-up cycle the door moves slowly from closed position to the fully open position to learning the leaf stroke.
At the end of the cycle a prolonged BEEP stands for the set-up to be completed.
e)
Now the door works according to the preset functions.