Configuring the contact on the STOP/INTERLOCK input between terminals 14-19 of
ET-LOGIC-B-board.
Select ON with normally open contact or when no device is connected to the input.
Select OFF when using a device with normally closed contact.
If S05 and/or S06 functions are set to ON only
Select ON if the monitored closing safety sensors have been installed (as required by standard EN
16005) to activate sensor test at the beginning of each cycle; select OFF only if the closing safety
sensors have not been set up to be monitored.
For more information, refer to "Safety sensors" paragraph.
If S07 and/or S08 functions are set to ON only
Select ON if the monitored opening safety sensors have been installed (as required by standard
EN 16005) to activate sensor test at the beginning of each cycle; select OFF only if the opening
safety sensors have not been set up to be monitored.
For more information, refer to "Safety sensors" paragraph.
Contact configuration on OPEN input between terminals 18-19 of ET-LOGIC-B board.
Select ON with normally open contact or when the OPEN input is not used.
Select OFF when using a device with normally closed contact.
Select ON only if a safety sensor has been installed on opening on input E.O.2.
Select ON only if a safety sensor has been installed on opening on input E.O.1.
Select ON only if a safety sensor has been installed on closing on input E.C.2.
If S09 and/or S10 functions are set to ON only.
Select test logic status, used by automation control unit to monitor safety sensors.
The set-up depends on the characteristics of sensor installed.
Most of the safety sensors on the market work with the test level low (OFF = default setting)
For more information, refer to "Safety sensors" paragraph.
The operator is ready for the set-up cycle.
Press the button (OK)
The control unit buzzer emits 4 beeps and starts the set-up cycle.
The door starts closing fully, then it performs an opening cycle at slow speed, which will be necessarily
succeded. At the end of the cycle a prolonged BEEP stands for the set-up to be completed.
After a while the door closes automatically.
Selec the work program selector.
OFF: Digital programmer ET-DSEL or T-NFC.
ON: Mechanical selector EV-MSEL.