26
NLB 60E Operation Manual
For obvious reasons, faults will be indicated
only when they occur.
Entering “Device type” provides a list of all device
model types:
Entering “Serial number” provides a list of all device
serial numbers:
Entering “Firmware version” will provide a list of the
current firmware versions of all devices:
Device: 1:1
Type: C 48:4
Device: 1:1
Ser#: 122222221
Device: 1:60
Ser#: 122222222
Device: 1:1
FW ver. 1.00
Device: 1:60
FW ver. 1.02
9.3.7 Subnet Faults
The Subnet Faults display shows the total number of
faults found in the Subnet as a number in the lower
left corner.
Press ENTER to display a list of the various faults.
If the number of faults is 0 and you press ENTER
anyway, this will take you to a display saying: “All
ok !”
When faults are indicated, press ENTER to scroll
through the list of faults using the SELECT UP/
DOWN arrow buttons.
The fault list is dynamic: if a fault is corrected or disap-
pears (e.g. temperature drops below fault threshold)
the display will switch over to the previous fault. “All
OK !” will be displayed when no faults are present.
General network faults are shown at the top, followed
by device specific faults.
Communication errors on NomadLink are displayed
as a percentage. 0% indicates no problems, 100%
indicates no communication at all
In case of communication errors, check cable con-
nections and general system setup.
Subnet Faults
110 Enter
Subnet 1
Com.errors XX%
9 oPeRAtIon AnD conFIGURAtIon