NLB 60E Operation Manual  

23

oPeRAtIon AnD conFIGURAtIon  9

9.3.5.1  NomadLink network settings

The DeviceControl application identifies a particular 
NLB 60E via the allocated Subnet number. This is 
displayed in the control views. The Subnet number 
is shown in the NLB 60E “Homepage” display. 

The Subnet number must be unique if more than 
one NLB 60E is connected on the same TCP/IP 
network. Press OK to edit, then use ADJUST | SET 
UP/DOWN to select a value. Press OK to confirm 
the new selection.

Closed Loop is a preference setting for fault indica-
tion. Select Yes or No.

If Yes is selected, the NLB 60E will report a fault 
if a Closed Loop connection is not detected on the 
NomadLink network.

If No is selected, no faults will be reported even if 
a Closed Loop is not detected. Use ADJUST | SET 
up/down to toggle between Yes and No. No is the 
default value.

9.3.5.2  DHCP settings

DHCP enables the NLB 60E to automatically obtain 
an IP address and Subnet Mask from the network. 

When  set  to  On,  the  function  is  similar  to  what 
happens when the PC displays “Obtain IP address 
automatically”. This requires that the functions of 
a  DHCP server be available on the network. Most 
standard network routers today offer this functional-
ity.

When set to No (default), the NLB 60E will use the 
manually entered IP address (default 192.168.1.166) 
and Subnet Mask (default 255.255.255.0).

Press OK to modify, and OK again to confirm new 
selection. When pressing OK you will see a display 
reading:

To activate the new settings, press the OK button to 
reboot. If you would like to verify that the settings 
have taken effect, check the “Bridge Info” pages.

Information note: DHCP is an acronym for Dynamic 
Host Configuration Protocol

9.3.5.3  TCP/IP network settings

At times you may find it necessary to change the 
IP address and Subnet Mask to allow the NLB 60E 
to function within a Local Area Network configura-
tion, or when using more than one NLB 60E in a 
larger system controlled by the DeviceControl editor 
software.

Press OK, and use the SELECT UP/DOWN arrows to 
move the cursor. Use the ADJUST | SET UP/DOWN 
arrows to change values. Press OK to verify or ESC 
to abort without saving the changes.

When pressing OK you will see the display read-
ing:

Содержание NLB 60E

Страница 1: ...Rev 2 00 Operation manual Item no OM NLB60E NLB 60E NomadLink Bridge and Network Controller...

Страница 2: ...duction and network requirements 12 7 1 2 Cable connections 12 7 1 3 Direct connection to PC peer to peer 12 7 1 4 Connection through Local Area Network LAN 12 7 2 TCP IP network setup instructions 12...

Страница 3: ...l Purpose Input GPI settings 24 9 3 5 5 Power Sequence delay setting 25 9 3 5 6 Front panel PIN code lock setting 25 9 3 5 7 Display contrast adjust 25 9 3 5 8 Security 25 9 3 6 Subnet Info 25 9 3 7 S...

Страница 4: ...d injury from tipping over Unplug this apparatus during lightning storms or when unused for long periods of time 13 Do not connect an amplifier output in parallel or series with any other amplifier s...

Страница 5: ...EMC EMI This equipment has been tested and found to comply with the limits for a Class B Digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection...

Страница 6: ...software to detect devices that are not currently turned on or connected to the mains This ensures very high reliability and redundancy while at the same time allowing connected amplifiers to remain...

Страница 7: ...ckaging 4 2 Mounting The NLB 60E is one rack unit high 1U and will fit into a standard EIA 19 rack The depth is 208mm 8 2 The weight is approximately 2 25 kg 5 lbs The NLB 60E may be mounted directly...

Страница 8: ...T ADJUST SET EXIT ESC ENTER OK NomadLink Subnet Power ON OFF NomadLink and Ethernet activity LEDs RJ45 Ethernet connector Ethernet on EtherCon housed RJ45 for standard PC using TCP IP NomadLink networ...

Страница 9: ...of the next amplifier until all amplifiers are connected Complete the network loop by connecting the OUT port of the last amplifier to the IN port on the NLB 60E The OUT port of the NLB 60E must be co...

Страница 10: ...a single subnet up to 60 units are located at some distance from each other the following general rules should be considered On the right side are typical examples of how NomadLink network setups can...

Страница 11: ...NLB 60E Operation Manual 11 CONNECTIONS TO AMPLIFIERS NOMADLINK 6...

Страница 12: ...ct connection between the PC and the NLB 60E forms a peer to peer network In most cases this connection will require use of the crossed Ethernet cable A crossed connection is necessary because the NLB...

Страница 13: ...er Using Windows XP as an example the following procedure will establish the proper IP settings 1 Go to START in lower left corner Select Connect to and Show all connections 2 Select Local Area Connec...

Страница 14: ...on features and functionality of this software When DeviceControl is running and con nected to an NLB 60E the front panel keypad commands on the NLB 60E s will be locked out However GPI trigger com ma...

Страница 15: ...Enabling of a secure connection is a two step process First the secure connection option must be enabled manually on each NBL 60E using the front panel keypad Then a password must be set in DeviceCont...

Страница 16: ...Press Set d 8 Press OK in the Settings dialog Secure Connection is now enabled in the additional NLB 60E s You can verify that a secure connection has been enabled by checking the NLB 60E information...

Страница 17: ...ore a new password can be entered The password also is reset when DeviceControl is uninstalled and reinstalled Entry of the old password is not required However depending on the Windows configuration...

Страница 18: ...ss ENTER OK to access the next menu down or to confirm a selection Press EXIT ESC to access the next menu up in the command tree This allows you to escape a selection without changing settings Use the...

Страница 19: ...information on this feature If an amplifier has been switched off locally and this was not the preconfigured status the NLB 60E will continue trying to switch it back on 9 2 4 Network LEDs and Ethern...

Страница 20: ...rk and display Subnet numbers and the total number of devices found on the Subnet This view is the default Homepage that will appear after a period of system inactivity It is also the view that is dis...

Страница 21: ...irmware version displays are provided for convenient review and to aid in technical support and troubleshooting The Serial Number is also displayed by a sticker on the rear panel of the NLB 60E The MA...

Страница 22: ...e NLB 60E s rear panel The GPI 1 is a Voltage sensing input detecting states above and below 12V DC GPI 2 and GPI 3 are identical contact closure inputs that detect an open or closed state The GPI Sta...

Страница 23: ...ar to what happens when the PC displays Obtain IP address automatically This requires that the functions of a DHCP server be available on the network Most standard network routers today offer this fun...

Страница 24: ...own keys to select the desired action Disabled shows as a dash Low High Ok Mute High Low Ok Unmute When you have made your selection press OK The following display allows the opposite action to be set...

Страница 25: ...om pensate for viewing angle and lighting conditions you may adjust the display s contrast Use up down arrow keys to make changes 9 3 5 8 Security Security Enter The Security configuration menu allows...

Страница 26: ...he various faults If the number of faults is 0 and you press ENTER anyway this will take you to a display saying All ok When faults are indicated press ENTER to scroll through the list of faults using...

Страница 27: ...vices Three different states are possible 1 Can t power ON NLB 60E is not able to power on the amplifier remotely No other fault can be Device 1 3 Can t power ON Device 1 5 Can t power OFF Device 1 5...

Страница 28: ...the tree structure is organized for the various features The headlines Level 1 are displayed at the right followed by sub views with subsequent displays for level 2 3 and 4 10 appendix Unlock UI PIN...

Страница 29: ...w Ok GPI2 Ok Mute Unmute Open Close Ok Close Open Ok GPI3 Ok Mute Unmute Security Enter Open Close Ok Secure conn Ok Enabled Reset password Ok Close Open Ok Secure conn Enable The password has been re...

Страница 30: ...ice 1 60 Ser 122222222 Device 1 1 FW ver 1 00 Device 1 60 FW ver 1 02 Device 1 3 Can t power ON Device 1 5 Can t power OFF Subnet 1 Com errors XX Open loop 14 1 17 2 Open loop 14 2 NLB 60E Level 1 Lev...

Страница 31: ...power off or 8 disconnect the Ethernet connection before you see the Succeeded to update window If you experience a failure in the update procedure due to loss of power or other unforeseen issues ple...

Страница 32: ...operate the NLB 60E s front panel features A When a PC running DeviceControl is connected to the NLB 60E and thus directly controlling the NomadLink subnet all commands from the front panel and GPI c...

Страница 33: ...character white text on blue background Yes x6 Yes x2 100 to 240 VAC 50 to 60 Hz auto select 35 W W 483 mm 19 H 44 mm 1 U D 208 mm 8 2 2 25 kg 5 lbs Black anodized aluminum front and painted steel ch...

Страница 34: ...y loss due to cancellation of any events or rent of replace ment equipment or costs due to a third party s or customer s loss of profit or any other indirect cost or losses however incurred Lab gruppe...

Страница 35: ...L a b g r u p p e n AB S w e d e n i n t e r n a t i o n a L c o n t a c t i n f o L a b g r u p p e n c o m U S CONTACT i n f o u s t c e l e c t r o n i c c o m w w w l a b g r u p p e n c o m...

Отзывы: