background image

User's Information

Document 1141A

User's Information for

SUMMIT

Modulating Condensing Boiler

Models SMB-200

SMB-250

H2211300A

WARNING

If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.

Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

nearby phone. Follow the gas supplier's
instructions.

• If you cannot reach your gas supplier, call

the fire department.

Installation and service must be performed by a
qualified installer, service agency, or gas
supplier.

FOR YOUR SAFETY:

 This product must be installed and serviced by a professional service technician,

qualified in hot water boiler installation and maintenance. Improper installation and/or operation could
create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death.
Improper installation and/or operation will void the warranty.

AVERTISSEMENT

Assurez-vous de bien suivres les instructions
données dans cette notice pour réduire au
minimum le risque d’incendie ou d’explosion ou
pour éviter tout dommage matériel, toute
blessure ou la mort.

Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareils.
• Ne touchez à aucun interrupteur. Ne pas vous

servir des téléphones dansle bâtiment où vous
vous trouvez.

• Appelez immédiatement votre fournisseur de

gaz depuis un voisin. Suivez les instructions
du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de

gaz, appelez le sservice des incendies.

L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié ou
par le fournisseur de gaz.

Содержание SUMMIT SMB-200

Страница 1: ...water boiler installation and maintenance Improper installation and or operation could create carbon monoxide gas in flue gases which could cause serious injury property damage or death Improper insta...

Страница 2: ...al Care 5 1B Annual Inspection of Flues and Vents 5 1C Shutting Down the Summit 5 1D To Restart Summit 5 1E Annual Inspection of Condensate Drain System 6 1F In the Event of Power Failure 6 1G Full Se...

Страница 3: ...the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not to...

Страница 4: ...r le plancher QUE FAIRE EN CAS D ODEUR DE GAZ N essayez pas d allumer n importe quelque appareil que ce soit Ne touchez pas un commutateur lectrique N utilisez pas le t l phone de votre r sidence Appe...

Страница 5: ...steps may require qualified service personnel 1D To Restart Your Summit Should the need arise you may have to restart your Summit Follow these steps 1 Momentarily depress reset button on top of contr...

Страница 6: ...conduct a detailed inspection of all flue product carrying areas of the boiler and vent system This should be done in accordance with the service instruction in the Installation and Operating Instruct...

Страница 7: ...eturn temperature below 39 F 4 C Figure 3 Typical Display Identification Codes Message 1H Trouble Shooting Fault Codes The Summit boiler is controlled by a Pactrol integrated boiler control PCB which...

Страница 8: ...rvice Advisors 20 Industrial Way Rochester NH 03867 603 335 6300 Fax 603 335 3355 Applications Engineering 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 0130 www Laars c...

Отзывы: