Residential Boilers
®
This can be a symptom of improper control strategy or
setpoints, or a load distribution problem. The controller in
the Unit includes an anti-short cycle (ASC) function. The
timer for the ASC can be set to delay the boiler start for a
specified time after a call for heat is completed.
11.F Temperature Sensors
High Limit Sensor -
The control uses a dual thermistor sensor to monitor
the Units maximum temperature. The high limit sensor
is installed in the outlet water. A dual thermistor sensor
is used, so that the two temperatures can be monitored
and compared to confirm accuracy. The control will
automatically reduce the firing of the Unit to prevent the
high limit from tripping. The high limit setpoint is factory set
at 195°. However, if desired you can set a lower limit using
the Adjustable High Limit function available from the Quick
Start menu.
Outlet Water Temperature -
The outlet water temperature is sensed by a dual
thermistor sensor, and is limit-rated. The control compares
the two temperature readings to determine accuracy. The
outlet sensor is used as the primary control point for high
limit, temperature operation, and modulation.
Inlet Water Temperature -
The inlet water temperature uses a single thermistor
sensor. The heat exchanger temperature rise (delta T) is
calculated using the inputs from the outlet and inlet sensor
temperatures.
Stack Limit -
The stack temperature is sensed by a dual thermistor
sensor, and is limit-rated. The control compares both of the
temperature readings to determine accuracy. The stack
sensor is used as a limiting feature to avoid excessive
temperatures in the vent.
11.G Diagnostics
Use the Diagnostics to check the status of the sensors and
the digital inputs and outputs. The system also records a
history of lockouts and alarms.
Analog Sensors -
You can use this display to check on operating
temperatures, fan speed, firing rate, etc. (The word
“analog” refers to values that can change continuously
between zero and a higher value.) The values shown here
are “Read Only” – you can’t change them from this display.
Digital Input/Output -
This display shows whether different functions, inputs
and outputs are either on or off. The functions listed here
include pumps, valves, alarms, etc. The values shown
here are “Read Only” – you can’t change them from this
display.
History
-
The system records the most recent lockouts or alerts. (If
there is a current lockout or alert, a note about this will also
appear at the bottom of the Home screen.)
• A “lockout” is a condition that will prevent the unit from
starting or running.
• An “alert” indicates a condition that is not normal. If it
continues, the control system might move to a “lockout,”
or the problem might be corrected.
11.H Error Codes
See Appendix B. on page 74
Содержание NEOTHERM NTH Series
Страница 4: ...LAARS Heating Systems...
Страница 24: ...Page 24 LAARS Heating Systems Figure 9 Hydronic Piping Single Boiler Zoning with Circulators...
Страница 26: ...Page 26 LAARS Heating Systems Figure 11 Hydronic Piping Multiple Boilers Zoning with Circulators...
Страница 33: ...Page 33 NEOTHERM Residential Boilers Figure 16 Control Panel Layout...
Страница 38: ...Page 38 LAARS Heating Systems Figure 19 Ladder Diagram 7 H Ladder Diagram...
Страница 67: ...Page 67 NEOTHERM Residential Boilers Figure 44 Heat Exchanger Components 68A 65 67 60 66 63 64...
Страница 68: ...Page 68 LAARS Heating Systems Figure 45 Electrical Components...
Страница 82: ...LAARS Heating Systems Notes...
Страница 83: ...NEOTHERM Residential Boilers Notes...