LAARS Heating Systems
EQUIVALENT LENGTHS OF STRAIGHT PIPE FOR TYPICAL SCH 40 FITTINGS
NOMINAL PIPE SIZE
FITTING
1/2” 3/4” 1” 1-1/4”
1-1/2” 2”
LINEAR FEET
90° ELBOW
3.6 4.4 5.2 6.6 7.4 8.5
TEE
4.2 5.3 6.6 8.7 9.9 12
Table 10.
SCH 40 METAL PIPE CAPACITY FOR 0.60 SPECIFIC GRAVITY NATURAL GAS
NOMINAL PIPE SIZE
@
0.30” W.C. PRESSURE DROP
LENGTH
1/2” 3/4” 1” 1-1/4”
1-1/2” 2”
FT
CUBIC FEET OF GAS PER HOUR
20 92 190 350 730 1100
2100
40 130 245 500 760 1450
60 105 195 400 610 1150
80
90 170 350 530 990
100
150 305 460 870
Table 11.
Unit
NATURAL GAS
REQUIRED
CU FT
SIZE
/ HR.
80
80
105
105
150
150
210 210
Table 9.
TO SIZE PIPING:
Measure linear distance from meter outlet to
last boiler. Add total input of all boilers and
divide by 1000 to obtain cu ft / hr required.
Add total equivalent length of fittings used
according to Table 10. Align total length (pipe
and fittings) on left side column of Table 11
with highest cubic feet of gas required.
SECTION 5 PUMP REQUIREMENTS
5.A Boiler Flow and Head Requirements
Table 12. Water Flow Requirements
Notes:
Consult and confirm with Applicable Fuel
Gas Code before beginning work.
Verify gas inlet pressure is between
4”
W.C. (1.0kPa)
and
13” W.C. (3.2kPa)
,
before and during operation.
Residential
table 13
Boiler Flow and Head Requirements
boiler only
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
gpm
feet
gpm
feet
gpm
feet
gpm
feet
gpm
feet
gpm
feet
gpm
feet
gpm
feet
gpm
feet
gpm
feet
80
10
26.8
7.6
16.9
6.1
11.7
5.1
8.65
4.3
6.5
3.8
5.28
3.4
4.3
3
3.6
2.8
3.1
2.5
2.7
105
13.3
38.8
10
23.3
8
15.6
6.7
11.3
5.7
8.48
5
6.7
4.4
5.4
4
4.5
3.6
3.8
3.3
3.2
150
19
39.4
14.3
24.1
11.4
16.3
9.5
11.9
8.1
9.03
7.1
7.19
6.3
5.9
5.7
4.9
5.2
4.2
4.8
3.6
210
26.7
28.1
20
15.6
16
9.88
13.4
6.88
11.3
4.86
9.9
3.71
8.9
3
8
2.4
7.3
2
6.7
1.6
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
Flow
H/L
lpm
m
lpm
m
lpm
m
lpm
m
lpm
m
lpm
m
lpm
m
lpm
m
lpm
m
lpm
m
80
37.9
8.2
28.8
5.2
23.1
3.6
19.3
2.6
16.3
2.0
14.4
1.6
12.9
1.3
11.4
1.1
10.6
0.9
9.5
0.8
105
50.3
11.8
37.9
7.1
30.3
4.8
25.4
3.4
21.6
2.6
18.9
2.0
16.7
1.6
15.1
1.4
13.6
1.2
12.5
1.0
150
71.9
12.0
54.1
7.3
43.2
5.0
36.0
3.6
30.7
2.8
26.9
2.2
23.8
1.8
21.6
1.5
19.7
1.3
18.2
1.1
210
101.1
8.6
75.7
4.8
60.6
3.0
50.7
2.1
42.8
1.5
37.5
1.1
33.7
0.9
30.3
0.7
27.6
0.6
25.4
0.5
residential
Boiler only
Boiler and Pump
Size
80
105
150
210
Size
80
105
150
210
Voltage
120V
120V
120V
120V
Voltage
120V
120V
120V
120V
FLA
2.0
2.0
2.0
2.0
FLA
2.8
3.8
3.8
4.0
MCA
2.5
2.5
2.5
2.5
MCA
3.5
4.8
4.8
5.0
MOP
15
15
15
15
MOP
15
15
15
15
40
45
50
55
60
15
20
25
30
35
8
11
14
17
19
22
25
28
31
33
Содержание NEOTHERM NTH Series
Страница 4: ...LAARS Heating Systems...
Страница 24: ...Page 24 LAARS Heating Systems Figure 9 Hydronic Piping Single Boiler Zoning with Circulators...
Страница 26: ...Page 26 LAARS Heating Systems Figure 11 Hydronic Piping Multiple Boilers Zoning with Circulators...
Страница 33: ...Page 33 NEOTHERM Residential Boilers Figure 16 Control Panel Layout...
Страница 38: ...Page 38 LAARS Heating Systems Figure 19 Ladder Diagram 7 H Ladder Diagram...
Страница 67: ...Page 67 NEOTHERM Residential Boilers Figure 44 Heat Exchanger Components 68A 65 67 60 66 63 64...
Страница 68: ...Page 68 LAARS Heating Systems Figure 45 Electrical Components...
Страница 82: ...LAARS Heating Systems Notes...
Страница 83: ...NEOTHERM Residential Boilers Notes...