background image

Mighty Venter Power Vent Systems

Page 5

Figure 1. Vent hood locations.

Table 3. Vent Pipe Reducer Kit.

3.

Vent Pipe Reducers
The applicable Part Numbers for the above are

listed in Table 2.

Carton #1

Carton #2

Carton #3

Boiler

Mighty

Power

Mighty

Vent

Vent Pipe

Model Venter Kit

Vent

Venter

Hood

Reducer Kit

Size

Order #

Model

Part #

P/N

Part #

500

20069301

MV2

20032600

D2000401

20070901

600

20069302

MV3

20032700

D2000402

20070902

715

20069303

MV3

20032700

D2000402

20070902

850

20069304

MV4

20032800

D2000402

20070903

1010

20069305

MV4

20032800

D2000402

20070904

1200

20069306

MV5

20032900

D2000403

20070905

1430

20069307

MV5

20032900

D2000403

20070906

1670

20069308

MV5

20032900

D2000403

20070907

1825

20069309

MV5

20032900

D2000403

20070906

NOTES:

1. Mighty Venter Kit #20069301 also includes the D2000500

transition ring for connection from Mighty Venter to vent hood.
(see note #7 on Figure 2 for more information).

2. Carton #1 includes Installation Instructions. Carton #2

includes one Installation Manual (specific to the Vent Hood). If
any items are missing from the package, contact Laars. Be
prepared with your purchase order number and the order
number on the shipping documents.

3. The contents of the “vent pipe reducer kit” are shown in Table

3.

Table 2. Part Numbers.

Boiler
Model

Vent Pipe

Reducer Kit

Part No.

Qty of

Reducers

In Box

REDUCERS IN CARTON

#1

Size

Part No.

#2

Size

Part No.

#3

Size

Part No.

#4

Size

Part No.

500

20070901

2

10-8

D2000302

8-6

D2000301

600

20070902

2

12-10

D2000303

10-8

D2000302

715

20070902

2

12-10

D2000303

10-8

D2000302

850

20070903

2

14-10

D2000304

10-8

D2000302

1010

20070904

4

16-14

D2000306

14-12

D2000305

12-10

D2000303

10-8

D20000302

1200

20070905

2

16-14

D2000306

14-10

D2000304

1430

20070906

2

18-14

D2000307

14-10

D2000304

1670

20070907

3

18-14

D2000307

14-12

D2000305

12-10

D2000303

1825

20070906

2

18-14

D2000307

14-10

D2000304

Dimensions shown in feet (m).

Vent Hood

7 (2.1) Minimum

Above Public

Walkway

Vent Hood

Vent Hood

1 (0.3) Above Grade

4 (1.2)

Minimum

Vent Hood Must Be

Mounted 4 (1.2)

Minimum Below Windows

3 (0.9m) Minimum

Vent Hood

4 (1.2)

Minimum

6 (1.8) Above Any
Outside Air Intake

Within 10 (3.0)

Vent

Hood

Содержание MV2

Страница 1: ...nstallation and or operation will void the warranty WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of...

Страница 2: ...General Information 1a Sizing 3 1b Installer Cautions 3 SECTION 2 Side Wall Vent Hood Location 2a Side Wall Vent Hood Location 4 SECTION 3 Installation 3a Inspection and Unpacking 4 3b Power Venter Mo...

Страница 3: ...1 the National Electric Code NFPA 70 or the Canadian Electrical Code CSA C22 1 and the Occupational Safety and Health Act OSHA 3 Any modifications to the Power Venter motor or wiring may void the warr...

Страница 4: ...peration 17 Ambient temperature surrounding Mighty Venter must not exceed 104 F 40 C 18 To prevent personal injury and equipment damage disconnect power supply to boiler or heater when working on Migh...

Страница 5: ...ludes one Installation Manual specific to the Vent Hood If any items are missing from the package contact Laars Be prepared with your purchase order number and the order number on the shipping documen...

Страница 6: ...nimum equivalent vent pipe length is 11 3 4m Slope Note 9 Supports Note 8 Vent pipe is customer supplied G H F J B Reducer dimensions For all sizes 1 2 3 4 B J Note 7 Clearances to combustibles 6 152m...

Страница 7: ...r 1 4 threaded rod with nuts and washers for mounting see Figure 3 for MV3 see Figure 4 for MV4 and MV5 The Mighty Venter may be mounted in any position as long as the shaft of the motor remains horiz...

Страница 8: ...he electrical box is mounted so that the fan proving switch is in a vertical position 2 Connect the aluminum tubing from the fan proving switch to the Mighty Venter housing using provided fittings 3d...

Страница 9: ...er Junction Box Mighty Venter NOTE The black BK and white W leads from the Mighty Venter to the junction box do not require field wiring on Model MV2 Color Legend BK Black W White R Red Y Yellow BL Bl...

Страница 10: ...LAARS Heating Systems Page 10...

Страница 11: ...Mighty Venter Power Vent Systems Page 11...

Страница 12: ...ville Ontario Canada Return Instructions After faulty component is determined ship inoperative part with proofs of purchase and installation date transportation prepaid directly to one of the addresse...

Отзывы: