background image

Laars Warranty

Mighty Venter Power Vent System

This Laars product is

backed by this warranty

to assure your complete satisfaction.

Laars warrants the components of this product either for one year from date of installation or 18 months from date of

purchase, whichever comes first. This warranty covers defects in material and workmanship. Products that are tampered

with, damaged, or defective due to malfunctioning appliances are not covered under this warranty. This warranty does not

cover the complete power vent system, only the defective parts.

The above warranty applies only if the installation and operation instructions applicable to the model are expressly and

completely followed. These instructions are furnished with the unit and are also available by writing the Laars factory. The

liability of Laars shall not exceed the repair or replacement of defective parts, excluding field labor.

FOB Factory: Rochester, NH or Oakville, Ontario, Canada.

Return Instructions: After faulty component is determined, ship inoperative part with proofs of purchase and installation

date, transportation prepaid, directly to one of the addresses listed below, Attention: Service Manager. Please include date

code of product with the defective component. The date code is listed on the product nameplate, which is located on the

electrical box or on the drip shield surrounding the motor. A copy of the original installation receipt must also be included

with returned components.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and by

province. Some states and provinces do not allow the exclusion or limitation of incidental damages, so the above limitation

or exclusion may not apply to you.

H2015300

B

800.900.9276 • Fax 800.559.1583 

(Customer Service, Service Advisors)

20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 

(Applications Engineering)

9 Brigden Gate, Halton Hills, Ontario, Canada L7G 0A3 (905) 203-0600  Fax: (905) 636-0666

www.Laars.com

              Litho in U.S.A. © Laars Heating Systems 0810  Document 7008B

Содержание MV2

Страница 1: ...nstallation and or operation will void the warranty WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of...

Страница 2: ...General Information 1a Sizing 3 1b Installer Cautions 3 SECTION 2 Side Wall Vent Hood Location 2a Side Wall Vent Hood Location 4 SECTION 3 Installation 3a Inspection and Unpacking 4 3b Power Venter Mo...

Страница 3: ...1 the National Electric Code NFPA 70 or the Canadian Electrical Code CSA C22 1 and the Occupational Safety and Health Act OSHA 3 Any modifications to the Power Venter motor or wiring may void the warr...

Страница 4: ...peration 17 Ambient temperature surrounding Mighty Venter must not exceed 104 F 40 C 18 To prevent personal injury and equipment damage disconnect power supply to boiler or heater when working on Migh...

Страница 5: ...ludes one Installation Manual specific to the Vent Hood If any items are missing from the package contact Laars Be prepared with your purchase order number and the order number on the shipping documen...

Страница 6: ...nimum equivalent vent pipe length is 11 3 4m Slope Note 9 Supports Note 8 Vent pipe is customer supplied G H F J B Reducer dimensions For all sizes 1 2 3 4 B J Note 7 Clearances to combustibles 6 152m...

Страница 7: ...r 1 4 threaded rod with nuts and washers for mounting see Figure 3 for MV3 see Figure 4 for MV4 and MV5 The Mighty Venter may be mounted in any position as long as the shaft of the motor remains horiz...

Страница 8: ...he electrical box is mounted so that the fan proving switch is in a vertical position 2 Connect the aluminum tubing from the fan proving switch to the Mighty Venter housing using provided fittings 3d...

Страница 9: ...er Junction Box Mighty Venter NOTE The black BK and white W leads from the Mighty Venter to the junction box do not require field wiring on Model MV2 Color Legend BK Black W White R Red Y Yellow BL Bl...

Страница 10: ...LAARS Heating Systems Page 10...

Страница 11: ...Mighty Venter Power Vent Systems Page 11...

Страница 12: ...ville Ontario Canada Return Instructions After faulty component is determined ship inoperative part with proofs of purchase and installation date transportation prepaid directly to one of the addresse...