Model LC (Australia) Pool and Spa Heater
Page 3
2C. Indoor Installation
The Laars Lite 2 Model LC (Australia) heater is
design-certified for indoor installation only when
equipped with a draft hood. Check the rating plate or
the parts list (Section 6) for the correct Laars draft
hood part numbers. Install the draft hood without
modification.
Connect the draft hood to a vent pipe which stops
at least 0.6 m above the highest point of the roof or
other object that is within 3 m of the flue. Install a
listed cap which allows a full equivalent opening for
flue products (see Fig. 3).
2C-1. Heater Clearance
Top of Heater
1.1 m Minimum
Blank side and
150 mm Minimum
rear of heater
Piping side
300 mm Minimum
Front of heater
450 mm Minimum
Floor
Noncombustible*
*If you are installing the heater on a combustible
surface, an approved noncombustible base must be
installed.
305 mm of
305 mm of
Figure 3. Indoor Installation Venting and Flueing
NOTE:
1.
The draft hood must sit directly on top of the heater as shown and must not be altered in any manner.
2.
An approved flue cowl must be fitted.
3.
Use approved roof fitting.
Table 1. Direct Air Openings
Required Net Free Opening Area (cm
2
)
Directly from Outside
Model
At Top
At Bottom
125
393
393
175
552
552
250
789
789
325
1023
1023
400
1260
1260
Table 2. Ducted Air Openings
Required Net Free Opening Area (cm
2
)
Ducted from Outside
Model
At Top
At Bottom
125
786
786
175
1104
1104
250
1578
1578
325
2046
2046
400
2520
2520
0.75
0.75
Roof jack
Roof jack
300 mm
Piping side
150 mm
Blank side
& Rear
300 mm
Piping side
150 mm
Blank side
& Rear