APPROXIMATE
TIME/TEMPERATURE
RELATIONSHIPS IN SCALDS
120°F (49
°
C) More than 5 minutes
125°F (52
°
C) 11⁄2 to 2 minutes
130°F (54
°
C) About 30 seconds
135°F (57
°
C) About 10 seconds
140°F (60
°
C) Less than 5 seconds
145°F (63
°
C) Less than 3 seconds
About 11⁄2 seconds
150°F (66
°
C)
About 1 second
155°F (68
°
C)
FIRST AID FOR SCALDS
1. Remove all wet clothing quickly. Wet clothing retains the heat.
2. Apply cold water to burned area for 30 minutes to reduce the heat in the skin and prevent deeper
burning. Never use butter, oils, or ointment to cover the burn. They may retain the heat.
3. Use a blanket to keep the scalded person warm.
4. Seek medical advice.
ERROR MESSAGES ON REMOTE TEMPERATURE CONTROL DISPLAY
The
LAARS
EVERHOT
®
tankless water heaters have the ability to monitor and display any
operating faults on the remote temperature control display. The error messages will display on the
monitor and will assist in servicing the water heater. The following is a listing of the error codes that may
flash on the remote monitor in case of a malfunction with the water heater. Please quote the code
displayed when calling for service.
Code
Displayed
Fault Remedy
10
Air supply or exhaust blockage
Check for a restriction in the exhaust vent.
11
No Ignition
Check to make sure the gas supply is on to the
water heater.
12
Flame Failure, grounding failure
Make sure gas is turned on at the water heater;
check for obstructions in exhaust vent.
14
Thermal Fuse
Heat exchanger overheated
16 Over
Temperature
Warning Excessive temperatures, wrong dip switch
setting, incorrect manifold pressure or gas type.
32
Outlet water temperature faulty
Outlet sensor or wiring may be defective
33
Heat exchanger outlet water temperature
faulty
H.E. outlet sensor or wiring may be defective.
34
Combustion air sensor faulty
Thermistor or wiring faulty
52
Modulating Solenoid Valve signal
abnormal
Check gas control and wiring
61
Combustion Fan Failure
Combustion fan or wiring faulty
71
Solenoid Valve Driving Circuit Faulty
Check all gas solenoids and wiring
72
Flame Sensing Device Faulty
Lack of flame sense – check flame rod and
wiring connections.
LC
Scale build-up in Heat Exchanger
Build up of lime scale in heat exchanger –
needs to be flushed.
(00)
(When checking maintenance code
history, “00” is substituted for “LC”).
If any of the above error codes are seen flashing on the remote display, call for service
.
WARNING
Failure to remedy faults may result in severe burns, scalds, and/or death.
34
Содержание Everhot IGE-199R Series
Страница 13: ...Recommended Piping for a Basic Installation Fig 2 13...
Страница 15: ...Recommended Piping for a Circulation System Fig 4 15...
Страница 22: ...Wiring Diagram WARNING DO NOT adjust any dipswitch settings on PC board 22...
Страница 23: ...Wiring Diagram Schematic 23...
Страница 38: ...SCHEMATIC DIAGRAM OF INTERNAL PARTS 38...
Страница 39: ...SECTION X PARTS LIST Cabinet Note Can purchase additional controls for remote locations 39...
Страница 40: ...Internal Components 40...
Страница 41: ...Internal Components 41...
Страница 42: ...Electrical Components 42...