SECTION II: SPECIFICATIONS
Max. Flow Rate @ Degree Temperature Rise
Max.
Input
Rating
Btu/hr.
Min.
Input
Rating
Btu/hr.
Temp Rise
40
°
F
60
°
F
80
°
F
100
°
F
120
°
F
Model No.
140
°
F
5
Flow Rate vs Temperature Rise Curve for EVERHOT
®
IGE model series
0
1
2
3
4
5
6
7
8
9
0
25
50
75
100
125
150
Δ
T – Temperature Rise (°F)
Max. Flow (gpm)*
*Note: The maximum flow is based upon a minimum water pressure of 30 PSI
Flow Rate
Gal/Min.
7.3 5.9 4.2 3.3 2.8 2.4
IGE-199R-10N
IGE-199R-10X
IGE-199C-5N
199,000
15,000
First Hour
Supply
Gal/Hr
.
438 354 252 198 168
IGE-199C-5X
144
Max. Flow Rate @ Degree Temperature Rise
Model No.
Max.
Input
Rating
kW/hr.
Min.
Input
Rating
kW/hr.
Temp Rise
22
°
C
33
°
C
44
°
C
56
°
C
67
°
C
78
°
C
Flow Rate
Liters/
Min.
27.6 22.3 15.9 12.5 10.6 9.1
IGE-199R-10N
IGE-199R-10X
IGE-199C-5N
IGE-199C-5X
58.3
4.4
First Hour
Supply
Liters/Hr
.
1656
1338
954 750 636 545
Содержание Everhot IGE-199R Series
Страница 13: ...Recommended Piping for a Basic Installation Fig 2 13...
Страница 15: ...Recommended Piping for a Circulation System Fig 4 15...
Страница 22: ...Wiring Diagram WARNING DO NOT adjust any dipswitch settings on PC board 22...
Страница 23: ...Wiring Diagram Schematic 23...
Страница 38: ...SCHEMATIC DIAGRAM OF INTERNAL PARTS 38...
Страница 39: ...SECTION X PARTS LIST Cabinet Note Can purchase additional controls for remote locations 39...
Страница 40: ...Internal Components 40...
Страница 41: ...Internal Components 41...
Страница 42: ...Electrical Components 42...