Recommended Piping for a Circulation System 

 
 

 

 
 

Fig. 4 

 

15

Содержание Everhot IGE-199R Series

Страница 1: ...ier call the fire department Installation and service must be performed by a qualified installer service agency or gas supplier WARNING If the information in these instructions is not followed exactly...

Страница 2: ...installed in accordance with local codes In the absence of local codes it must be installed in compliance with the National Fuel Gas Code ANSI Z223 1 Latest Edition or in Canada CAN CGA B149 1 Natural...

Страница 3: ...et piping of this water heater It is the responsibility of the installing contractor to see that all controls are correctly installed and are properly operating when the installation is complete DO NO...

Страница 4: ...all a qualified service agency to inspect the appliance and to replace any part of the control system including gas controls which has been under water DO NOT attempt to use this water heater with any...

Страница 5: ...e maximum flow is based upon a minimum water pressure of 30 PSI Flow Rate Gal Min 7 3 5 9 4 2 3 3 2 8 2 4 IGE 199R 10N IGE 199R 10X IGE 199C 5N 199 000 15 000 First Hour Supply Gal Hr 438 354 252 198...

Страница 6: ...ximum input 0 9 Minimum input Venting System Forced Combustion external vent For Outdoor Installation Only Setpoint Temperature Without remote temperature control 140 F Commercial models 120 F Residen...

Страница 7: ...kg and can be installed by 1 person The burners ignite within 3 seconds of water flow 1 2 gallon minute 1 9 L m minimum by direct spark ignition There is no standing pilot A variable speed combustion...

Страница 8: ...ble Contact your gas supplier or plumbing professional for more information Liquefied petroleum gases propane gas is heavier than air and will remain at floor level if there is a leak Basements crawl...

Страница 9: ...eat temperatures are necessary to obtain adequate booster output add an ASSE approved mixing valve for hot water supplied to fixtures UNPACKING INSPECT SHIPMENT carefully for any signs of damage 1 All...

Страница 10: ...erhangs windows doors etc Also avoid locations where there is heavy water runoff from roofs Determine the proper height and location for the water heater to be installed Consider the water and gas con...

Страница 11: ...3 ppm Up to 0 05 ppm Up to 5 ppm Lime Condition Warning Signal If the EVERHOT water heater is operated under hard water conditions without a water conditioner the error code LC may flash on the remote...

Страница 12: ...ris Debris will clog the mesh strainer of the inlet filter The inlet strainer prevents debris from damaging the flow sensor or clogging the coil It may need to be cleaned periodically and should be cl...

Страница 13: ...Recommended Piping for a Basic Installation Fig 2 13...

Страница 14: ...illustration The drain solenoids are recommended for very cold climates to prevent water heater freeze damage where power failures from ice and windstorms occur The electrical connections for the two...

Страница 15: ...Recommended Piping for a Circulation System Fig 4 15...

Страница 16: ...Recommended Piping for Back up Storage System For hotels motels and other high flow applications Fig 5 Note The Primary Circulator for the water heating loop must be sized for 21 GPM 35 Ft Head 16...

Страница 17: ...stall the pressure relief valve into a tee connection from the hot water outlet of the water heater Note Some models may already be equipped or supplied with an installed pressure relief valve Verify...

Страница 18: ...uch as through improper testing of gas lines or emergency malfunction of the supply system the gas valve must be checked for safe operation Make sure that the outside vents on the supply regulators an...

Страница 19: ...9 12 15 18 21 24 27 30 38 45 53 61 3 4 278 190 152 130 115 105 96 90 84 79 72 64 59 55 1 520 350 285 245 215 195 180 170 160 150 130 120 110 100 1 1 4 1050 730 590 500 440 400 370 350 320 305 275 250...

Страница 20: ...around the plugs 7 Replace the front control panel Restore electrical power to the water heater NOTICE If the gas supply pressure is below the specified value check the gas piping to insure that it is...

Страница 21: ...by local code then provide a three wire GFI grounding type receptacle within reach of the control box Provide a grounded line cord and connect to the black and white power supply and green ground scr...

Страница 22: ...Wiring Diagram WARNING DO NOT adjust any dipswitch settings on PC board 22...

Страница 23: ...Wiring Diagram Schematic 23...

Страница 24: ...re for sanitizing purposes Always check water temperature by hand before entering the shower or bath The temperature may have been changed Test the temperature of the water with your hand or elbow bef...

Страница 25: ...or the cable using a 1 4 6 4 mm drill bit 3 Run the cable from the control to the water heater or another control which ever is closer or more convenient 4 Remove the face plate from the remote contro...

Страница 26: ...e setting is 140 F In addition the control will display fault codes in the event the water heater needs service Up to two additional optional remote controls may be purchased and installed if desired...

Страница 27: ...ontrols with the power on to the water heater There are 120 volt terminals and wiring next to the remote control connections inside the unit All servicing and wiring must be performed by a qualified i...

Страница 28: ...vice professional 1 Flooding to or above the level of the burner or controls 2 External firing 3 Damage 4 Firing without water 5 Sooting NEVER OPERATE THE WATER HEATER WITHOUT FIRST BEING CERTAIN IT I...

Страница 29: ...ely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department OPERATING INSTRUCTIONS 1 STOP Read the safety i...

Страница 30: ...er lines A licensed plumbing professional or local plumbing authority should be consulted CAUTION This water heater when set at a lower temperature setting is not capable of producing hot water of suf...

Страница 31: ...o 9 error codes if any stored in memory that has been experienced Any error codes will be displayed on the digital monitor in sequence starting with the most recent code 7 To display the water flow th...

Страница 32: ...matically start heating water whenever a hot water faucet is opened The remote temperature control s will indicate hot water use with the green IN USE indicator 5 All controls can also display diagnos...

Страница 33: ...any faucet in the system Be careful whenever using hot water to avoid scalding injury Certain appliances such as dishwashers and automatic clothes washers may require increased temperature water By se...

Страница 34: ...yed Fault Remedy 10 Air supply or exhaust blockage Check for a restriction in the exhaust vent 11 No Ignition Check to make sure the gas supply is on to the water heater 12 Flame Failure grounding fai...

Страница 35: ...Check the front vent outlet for any obstructions 4 All electric motors are permanently lubricated and do not need oiling Remove the combustion air blower and clean wheel and housing with soft brush or...

Страница 36: ...ut the lime deposits Use the following procedure and diagram fig 13 to flush the heat exchanger and remove the lime scale 1 Disconnect power to the water heater 2 Close valves in the cold water inlet...

Страница 37: ...erate the water heater To remedy this situation either increase the total water flow from the tap or using the remote temperature controller decrease the setpoint temperature of the water heater to th...

Страница 38: ...SCHEMATIC DIAGRAM OF INTERNAL PARTS 38...

Страница 39: ...SECTION X PARTS LIST Cabinet Note Can purchase additional controls for remote locations 39...

Страница 40: ...Internal Components 40...

Страница 41: ...Internal Components 41...

Страница 42: ...Electrical Components 42...

Страница 43: ...ber Front Plate 1 116 Spark Electrode 1 117 Flame Sense Rod 1 118 Electrode Gasket 1 119 Electrode Holder 1 120 Upper Combustion Chamber Gasket 1 122 Fan Casing Assembly 1 123 Blower Motor 1 127 Blowe...

Страница 44: ...805 Screw 3 806 Screw 4 807 Washer 4 808 Screw 4 809 Screw 4 810 O Ring 3 813 O Ring 2 814 O Ring 2 815 O Ring 2 817 O Ring 1 818 Gasket 2 238 44959 00 Installation and Operating Instructions 1 239 4...