INSTRUCTION MANUAL FOR THE INSTALLER
LSI 001 -EN- REV. 06
95
COMpACT RANGE and S5 1 GROUp
6
Carry out the following procedures referring to the chapter “parts” on page 90.
NOTE. The electronic control board automatically controls the two group delivery control versions
(Ep or EK).
6.1
Ep MODEL
This model is equipped with an electronic control board which controls the water level in the boiler,
and the activation of the motor pump and of the cup warmer heating element (optional).
It also controls possible malfunctions to be viewed on the display.
OpERATING TEMpERATURE ADJUSTMENT FOR THE ELECTRIC HEATING SYSTEM
The electric heating system of the appliance is already set by the manufacturer to operate at a temperature
of
120 °C in the boiler, corresponding to 1 bar boiler pressure. Boiler pressure is viewed on the pressure
gauge (4) situated on the front panel of the appliance.
In order to increase or decrease the boiler pressure,
it is necessary to operate on the electric pressure
switch (Pict 20) which is inside the machine (on the
right side), as indicated here below:
• Turn the adjustment screw anti-clockwise to
increase boiler pressure.
• Turn the adjustment screw clockwise to decrease
it.
Boiler pressure (at operating temperature) is normally modified exclusively in order to adapt the machine
temperature to the particular type of coffee blend so as to obtain the best result in the cup.
ELECTRIC CUp WARMER (optional)
In the models equipped with the electric cup warmer, to activate it, move the main switch button (3) from
position
1 (standard operation of the machine) to position 2. To deactivate it, move it back to position 1.
6.2 ALARM CONTROL – Ep MODEL
This model communicates any anomalies through the relevant symbols on the control panel and
touchpads.
TOUCHPAD SYMBOLS FLASHING ALTERNATELY:
• The automatic refill system for the boiler has been operating for longer than
3 minutes (total block of
all machine operations). To return to normal operation, turn off the machine with the main switch. If
the problem is repeated, check the automatic refill system of the boiler.
WARNING!
Cut off power while operating on the pres-
sure switch.
20
00
8
ADJUSTMENT SCREW
PRESSURE SWITCH