INSTRUCTION MANUAL FOR THE INSTALLER
LSI 001 -EN- REV. 06
51
• SETTING MENU FOR “ON/OFF” BUTTON (Word “OFF:On” flashing): this menu is used to activate
or deactivate the “ON/OFF” free flow button for all delivery groups.
•
TEMpERATURE MIX SETTING MENU FOR HOT WATER FOR INFUSIONS (Word “MIX” flashing):
this menu is used to enable the temperature mix mode for hot water delivery for infusions.
NOTE. While scrolling through these menus, 60 seconds after any button has been pressed, the
display will return to standard operation mode (pict 16 – page 42). To quit the programming phase
before the 60 seconds have passed, press and hold down the button
for about 5 seconds; the
data set previously will be stored to memory.
•
TIMER MENU
1. Press the button
and hold it down for about 5 seconds; the display will show the flashing
symbols
and “
p”.
2. Press the button
to open the
TIMER menu, the display will show:
Where “
OFF” is shown by default.
1. If you confirm “OFF”, using the button
, this quits the
TIMER menu and the display goes back to
showing the blinking symbols
and “
p”.
If, by pressing the button
you select “
ON”, the symbol
disappears and if you confirm it with the
, button, you will open the menu for the weekly switching “ON” and “OFF” time of the appliance.
The display will read:
where the numbers indicating switching on time for Monday “
DAY 1” are flashing.