Troubleshooting
• This espresso machine is equipped with several feedback mechanisms that alert the operator when an unusual condition occurs.
Additionally the espresso machine will warn the operator when certain parameters fall below or above the programmed point. These
errors and warnings will appear as a message in the display.
• The following section will describe errors and warnings that may appear in the display.
Description
Message Solution
Message
This message is displayed when the CPU does not detect
a full signal from the steam boiler within the set time
interval.
When this message is displayed the CPU also shuts down and turns off power to the machine (see the parameter
“Level Timeout”). Press the ON/OFF button to reset this error.
Steam Boiler
Autofill Failed
Coffee Boiler 1
Probe Failed
This message is displayed when the CPU does not detect
the temperature probe.
When this message is displayed the CPU shuts down and turns off the machine.
The way to reset this error is to verify and to reconnect the temperature probe.
SB Filled?
This message is displayed during first installation and
when preset of settings is made.
Push enter if Steam Boiler is filled. Verify the presence of water looking the sight glass.
Groups Blend?
This message is displayed during first installation and
when preset of settings is made.
Push enter if groups have been blend ie no air is present in groups.
Coffee Boiler 1
Is Not Heating
This message is displayed when the coffee boiler
does not reach the minimum temperature with the
programmed time interval.
See the parameter “Heating Timeout” for more information. The number on the display corresponds to the
number of the faulty coffee boiler.
Coffee Boiler 1
Overheated
This message is displayed when the coffee boiler
temperature exceeds the maximum allowed
temperature.
When this message is displayed call an authorized service technician to repair this fault. The also CPU turns
power off to the coffee boiler.
Steam Boiler
Probe Failed
This message is displayed when the CPU does not detect
the temperature probe.
When this message is displayed the CPU shuts down and turns off the machine.
The way to reset this error is to verify and to reconnect the temperature probe.
Steam Boiler
Overheated
This message is displayed when the steam boiler
temperature exceeds the maximum allowed
temperature.
When this message is displayed call an authorized service technician to repair this fault. The also CPU turns
power off to the steam boiler.
Steam Boiler
Is Not Heating
This message is displayed when the steam boiler
does not reach the minimum temperature with the
programmed time interval.
See the parameter “Heating Timeout” for more information.
Flow Meter 1
No Pulse
This message is displayed when the CPU does not
receive the appropriate signal from the flowmeter.
When the flowmeter alarm is displayed, push a button to turn off the alarm. This problem is a result of water not
flowing through the flow meter. This can be caused by the coffee packed too tightly, a blockage in the tubes, a
malfunctioning water pump, a faulty valve, or a damaged flowmeter. Call a service technician to fix this problem.
Autofill In
Progress
This message is displayed when the steam boiler autofill
cycle is activated and water is entering the steam boiler.
No action is required when this message is displayed. This message is only displayed to notify the operator of
the active process.
Invalid
Password
This message is displayed when password entered does
not match the programmed password.
This error message will be displayed anytime an incorrect password is entered.
The machine comes back to the previous state.