EN
41
Display
Operating Procedure
Description
Programming Mode
Press the T3 button to enter the menu, move with the buttons T1 and T2 to set the desired
temperature, press the T3 button to confirm the value. In the case of espresso machine with 4 groups you can
set this value also on the coffee boiler 2.
Press the T3 button to return to the “Technical” programming.
Press T1 or T2 to continue with the programming of the other parameters.
To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed.
Press the T3 button to exit the menu and return to the normal use of the espresso machine.
Alternatively, you can exit the “Technical” programming and return to the normal use of the espresso machine by
pressing T2 and T3 at the same time.
5
8
9
Coffee Boiler
Settings
Coffee Boiler
“Technical” Programming
CB1 Offset
3.0
°
C
• The OFFSET parameter is used to calibrate
the coffee boiler temperature system to
ensure the display temperature accurately
represents the temperature of the water
exiting the group head.
• This parameter is preset at the factory
based upon initial tests of this espresso
machine.
• It is not recommended that this number
is changed. Changes to this parameter can
cause unexpected results.
• It is important to write down this value
before making changes to be sure you
can return to the factory programming if
unexpected results occur. Each machine
may have a different value as it is set
individually.
THE STEAM BOILER CONTAINS WATER AT ELEVATED TEMPERATURES. WATER
TEMPERATURE OVER 52°C CAN CAUSE SEVERE BURNS INSTANTLY OR DEATH
FROM SCALDING.
DANGER
CB Settings
Exit
6
LaMarzocco 00:00
CB 93.8
°
C SB
7
Exit
Menu
Содержание Linea PB