Display
Operating Procedure
Description
“Barista” Programming
Preinfusion
Settings
Pre-Infusion or Pre-Brewing
• This parameter allows the operator to
program the time of pre-brewing of
water with the coffee. Each group can
have a different programming.
• Pre-brewing has only two values to be
adjusted for each group. The time (in
seconds) for which the brewing valve
is open during the pre-brewing cycle
and the time (in seconds) for which
the brewing valve is closed during the
pre-brewing cycle; during this time the
pump is active. Once the pre-brewing
cycle is over, the normal brewing cycle
will continue until the end.
• For an espresso machine composed
of three groups, they are identified as
Group 1, Group 2 and Group 3.
Group 1 Pre-Inf
0s Wet
Group 1 Pre-Inf
0s Hold
5
Press
T1
or T2 to select the group whose parameters you want to set.
By pressing the T3 button
the first value will blink. Use the buttons
T1 and T2
to reach the value that you want
to set, press T3
to confirm. Repeat this operation to set the second value.
Preinfusion
Exit
6
Press T1 or T2 until the display shows the exit menu, press the T3 button to return to the “Barista” programming.
7
Press T1 or T2 to continue with the programming of the other parameters.
94.4 00:00
95.5 95.1 SB
8
Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso
machine.
Group Dose