Operating Procedure
26
La Marzocco, S.r.l. Firenze, Italia
Version 1.3
Temperature Correction
Technician Level Parameters
•
This parameter allows the technician to adjust the
temperature of the individual coffee boilers.
•
This procedure is best completed with an external
temperature measuring device that measures the
water exiting the group at the point of contact with
the coffee.
Password
?????
LaMarzocco 09:30
Language
English
Temp.correction
Temperatures
Press and hold the
button on the group 1 keypad until the following is displayed
(approximately 10 seconds):
Enter the 5 digit technician password using buttons 1-5 on the group 1 keypad. Once accepted the
following appears:
1
2
Press the
button on the group 1 keypad until the following appears (one time):
3
Press the
or the
button to adjust the temperature higher or lower. Each block is equal to
0.5°F. Once the desired setting is made press the button
to confirm and advance to the next
boiler (if available).
5
MODE
+
When finished, continue to the next parameter or press
to exit programming mode.
7
ON
OFF
Temp.correction
Temperatures
MODE
Coffee Boiler 1
Press the
button on the group 1 keypad one time and the following appears:
4
ENTER
Repeat procedure 5 for all subsequent boilers.
6
Software Programming Manual - ENG - V 1.3.pmd
30/10/2006, 14.39
26