GB/5 - FB/80
Factory Level Parameters
PID Range
PID Range
5
°
F
•
This parameter sets a range in which the PID
algorithm is active.
•
This parameter is preset at the factory based upon
theoretical calculations and physical experiments.
•
It is not recommended that this number is changed.
•
Changes to this parameter can cause unexpected
results.
•
It is important to write down the number before any
changes are made to make sure you can return to
the factory programming if unexpected results occur.
•
Experienced technicians may wish to experiment
with different values.
•
The lowest value for this parameter is 3.6.
Password
?????
LaMarzocco 09:30
Groups Number
3
PID Range
5
°
F
Press and hold the button on the group 1 keypad until the following is displayed (approximately 10
seconds):
Enter the 5 digit factory password using buttons 1-5 on the group 1 keypad. Once accepted the
following appears:
1
2
Press the
button on the group 1 keypad until the following appears (four times):
3
Press the
or the
button to change the value of the parameter. When the desired value is
displayed press to
confirm value.
4
When finished, continue to the next parameter or press
to exit programming mode.
5
MODE
+
ENTER
ON
OFF
Software Programming Manual - ENG - V 1.3.pmd
30/10/2006, 14.39