Display
Operating Procedure
14
La Marzocco, S.r.l. Firenze, Italia
Version 1.3
Autosteam Parameter Settings
Factory Level Parameters
•
When the parameter Autosteam is set to ENABLED,
this parameter is enabled.
•
This parameter is set at the factory when the
Autosteam option is ordered.
•
To accurately measure milk temperature, an external
temperature measuring device should be used.
Changes to the values contained in this parameter
should be done based upon the external temperature
measuring device
•
Each Autosteam wand may be assigned to a specific
keypad. The 6th button on the assigned keypad
activates the Autosteam function. There is a
maximum of 2 Autosteam steaming wands.
Password
?????
LaMarzocco 09:30
Groups Number
3
Autosteam
Data programming
Autosteam
Data programming
Autosteam group1
0
Press and hold the
button on the group 1 keypad until the following is displayed
(approximately 10 seconds):
Enter the 5 digit factory password using buttons 1-5 on the group 1 keypad. Once accepted the
following appears:
1
2
Press the
button on the group 1 keypad until the following appears (about seven times):
3
Press the
or the
button to change the value of the flashing parameter. The first value
assigns the Autosteam function to a specific keypad (0 = non-active).
5
MODE
+
When finished, continue to the next parameter or press
to exit programming mode.
7
ON
OFF
Press the
button on the group 1 keypad to access the settings for this parameter.
4
ENTER
Press the
button on the group 1 keypad to access the temperature value. The current
measured temperature appears on the left and the set temperature appears on the right (flashing).
Press the
or the
button to adjust the temperature then press to confirm.
6
ENTER
Autosteam Temp 1
150.0
°
F 149.0
°
F
+
ENTER
Software Programming Manual - ENG - V 1.3.pmd
30/10/2006, 14.39
14