MODEL TPS - INSTRUCTIONS AND TROUBLESHOOTING INFORMATION

3 OF 20

CPN 40615

PERSONAL PRECAUTIONS:

1.

 

Someone should be within range of your voice or close enough to come to your aid when you

work near a battery.

2.

 

Have plenty of fresh water and soap nearby in case the battery electrolyte contacts skin,

clothing, or eyes.

3.

 

Wear complete eye protection and clothing protection. Avoid touching eyes while working near a

battery.

4.

 

If the battery electrolyte contacts skin or clothing, wash immediately with soap and water.  If

the electrolyte enters the eye, immediately flood the eye with running cold water for at least ten
(10) minutes and get medical attention immediately.

5.

 

Never smoke or allow a spark or flame in vicinity of a battery.

6.

 

Be extra cautious, DO NOT drop metal onto a battery.  It might spark or short-circuit the battery

or cause an explosion.

7.

 

Remove personal metal items such as rings, bracelets, necklaces, and watches when working

with a battery.    A battery can produce a short-circuit current high enough to weld these items

causing severe burns.

8.

 

NEVER charge a frozen battery.

PREPARING TO CHARGE

1.

 

If it is necessary to remove the battery connections, always remove grounded the terminal from the

battery first.  Make sure all loads are disconnected and unit is off, so as not to cause an arc.

2.

 

Be sure the area around the battery is well ventilated while the battery is being charged.

3.

 

When cleaning battery terminals, be careful to keep corrosion from coming in contact with eyes.

4.

 

Study all the battery manufacturer’s specific precautions such as removing or not removing cell caps
while charging, recommended rates of charge, and maintenance procedures.

UNIT LOCATION

 

Never place this unit directly above the standard flooded battery.  Gases from the battery will

corrode and damage equipment.  A sealed maintenance free or valve regulated lead acid
(VRLA) may be placed below this equipment.

 

Never allow the battery electrolyte to drip on this unit when reading the specific gravity or

filling the battery.

 

Do not operate this unit in a closed-in area or restrict ventilation in any way.

 

Do not set any battery on top of this unit.

D.C. CONNECTION PRECAUTIONS

Connect and disconnect d.c. output cables only after setting all of this unit's switches to off position and

removing a.c. input supply.

GROUNDING INSTRUCTIONS

This battery charger should be connected to a grounded, metal, permanent wiring system; or an
equipment grounding conductor should be run with circuit conductors and connected to equipment-

grounding terminal or lead on battery charger.  Connections to battery should comply with all local
codes and ordinances.

CAUTION:  DO NOT PULL ON OUTPUT CABLES WHEN DISCONNECTING CHARGER FROM BATTERY.

Содержание TPS

Страница 1: ...20 CPN 40615 MODEL TPS BATTERY CHARGER TruPowerSource ECN DATE 14575 2 01 13374 9 99 9525 5 95 13608 1 00 13243 8 99 9359 2 95 106 BRADROCK DRIVE DES PLAINES IL 60018 1967 847 299 1188 FAX 847 299 306...

Страница 2: ...Incorrect re assembly may result in a risk of electric shock or fire To reduce risk of electric shock disconnect this unit from the a c supply or batteries and loads before attempting any maintenance...

Страница 3: ...ected and unit is off so as not to cause an arc 2 Be sure the area around the battery is well ventilated while the battery is being charged 3 When cleaning battery terminals be careful to keep corrosi...

Страница 4: ...y of the claim to La Marche Mfg may void warranty service for any physical damages reported for repair HANDLING WARNING Equipment can be very heavy and top heavy Use adequate manpower or equipment for...

Страница 5: ...ld Ground Terminal 7 5 Mounting 7 6 Power Cabling Formulas 8 0 ELECTRICAL CONNECTIONS FIELD WIRING 8 1 A C Input 8 2 D C Output 8 3 Remote Voltage Sensing 8 4 Load Sharing 8 5 Alarm Connections 9 0 OP...

Страница 6: ...he TPS series rectifiers provide separate voltage adjustments for floating or equalizing lead or nickel cadmium cells The float or equalize mode of operation is selected by a switch located on the fro...

Страница 7: ...of 10 of nominal The 75 and 100 amp units are rated for three phase inputs and available in 208 240 or 480 Vac inputs 3 2 INPUT FREQUENCY RANGE 57 to 63 Hz 60 HZ nominal 47 to 57 HZ 50 HZ nominal 3 3...

Страница 8: ...is in the float mode of operation Equalize Indicator A yellow LED illuminates to indicate that the rectifier is in the equalize mode of operation NOTE REFER TO INFORMER ACCESSORY ALARM PACKAGE SECTION...

Страница 9: ...apable of operating in an ambient relative humidity range of 0 95 non condensing 6 4 SHOCK The rectifier in its shipping container withstands shock developed when one edge of the container is dropped...

Страница 10: ...t terminals and the battery at less than volt when the unit is fully loaded See Section 7 6 for POWER CABLING FORMULAS The total loop length is twice the distance from the wiring point to the unit 7 2...

Страница 11: ...ng section may be used to calculate the wire size requirements for wire lengths in excess of 10 ft Refer to TABLE 3 CMA CROSS SECTION OF WIRE IN CIRCULAR MILS A CURRENT DRAIN IN AMPERES LF CONDUCTOR L...

Страница 12: ...ifier To prevent the d c output fuse from blowing when connecting the battery connections to the power supply and batteries should be done in the following order single power supply 1 Connect a c inpu...

Страница 13: ...perly If the unit is not operating correctly check the connections again and read Section 12 TROUBLE SHOOTING 10 0 ADJUSTMENTS 10 1 CURRENT LIMIT ADJUSTMENT The current limit adjustment is factory set...

Страница 14: ...the resonating winding of PT which reduces the transformer output and lowers the unit output voltage In the current limit mode the triac is also fired to regulate the unit output current in the same...

Страница 15: ...ing 2 Check unit specifications with customer order 3 Check input connections input voltage and line breaker size 4 Check for shipping damage loose connections broken wires etc 5 Certain failures can...

Страница 16: ...ze adjustment procedure for proper voltage setting Disconnect battery and loads from rectifier output terminals put F E switch in the float position and apply a c input voltage to rectifier If d c vol...

Страница 17: ...ator assembly S2A 188 is defective 3 Open gate on triac TR 1 12 3 5 Ground and short circuit test A simple ohmmeter check can be performed to check the unit for a short to ground primary to secondary...

Страница 18: ...ates an open gate and the triac should be replaced A good device should have resistance in both directions but not zero ohms 12 5 TROUBLESHOOTING AND REPLACING POWER SILICON DIODES MODULES The procedu...

Страница 19: ...harge Connect the meter test leads to the capacitor leads or terminals and observe indicated resistance A good capacitor will indicate an initial low resistance and gradually increase as the capacitor...

Страница 20: ...es will apply A purchase order to cover the labor and transportation cost is required prior to the deployment of the service representative In accepting delivery of the equipment the purchaser assumes...

Страница 21: ...MODEL TPS INSTRUCTIONS AND TROUBLESHOOTING INFORMATION 21 OF 20 CPN 40615 INSERT PICTURE PIC TPS PAGE1...

Страница 22: ...MODEL TPS INSTRUCTIONS AND TROUBLESHOOTING INFORMATION 22 OF 20 CPN 40615 INSERT PICTURE PIC TPS PAGE2...

Страница 23: ...MODEL TPS INSTRUCTIONS AND TROUBLESHOOTING INFORMATION 23 OF 20 CPN 40615 INSERT PICTURE PIC TPS PAGE3...

Страница 24: ...MODEL TPS INSTRUCTIONS AND TROUBLESHOOTING INFORMATION 24 OF 20 CPN 40615 INSERT PICTURE PIC TPS PAGE4...

Отзывы: