where
is the total load power taken from digital DO outputs in the "1" state (only for
loads connected to the GND circuit);
— power load removed from the DAC outputs;
— power load, taken from the output of +15 V;
— power load, taken from the output of -15 V;
— power load, taken from the output of +3.3 V;
In turn, the power summands
of the corresponding i-th outputs must be calculated either
through the known load current
by the formula
, or through the known load
resistance
at the i-th output
The power summands
of the corresponding j-th outputs must be calculated either through
the known load current
by the formula
, or through the known load resistance
at the j-th output
The power
and
should also be calculated either through known load currents
by formulas
,
or through a known load resistance
, according to
formulas
,
All terms in the power formulas are positive, dimension: power — Watt, current — Ampere,