Tradesman Construction Heaters
www.lbwhite.com
Owner’s Manual • Tradesman
10
-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identi
fi
ed and
repaired before proceeding.
9. A quali
fi
ed service agency must check for proper
operating gas pressure upon installation of the
heater.
10. Always use pipe thread compound that is
resistant to propane and natural gas on threaded
connections.
11. Light according to instructions on heater or within
owner’s manual.
12. Make sure the heater has the proper gas regula-
tor for the application. A regulator must be con-
nected to the gas supply so that gas pressure
at the inlet to the gas valve is regulated within
the range speci
fi
ed on the dataplate at all times.
Contact your gas supplier, or the L.B. White Co.,
Inc. if you have any questions.
13. This heater is con
fi
gured for use for propane gas
vapor withdrawal only. Do not use the heater
in an propane gas liquid withdrawal system or
application. If you are in doubt, contact the L.B.
White Co., Inc.
14. The heater must be installed so as not to inter-
fere with or obstruct normal exits, emergency
exits, doors and walkways.
15. Railing, fencing or suitable substitute materials
must be used to keep the heating equipment
from any people using and visiting the structure.
16. Eventually, like all electrical/mechanical devices,
the thermostat can fail. Thermostat failure
may result in an underheating condition. The
thermostat should be tested to make sure it
turns the heater on and off within a temperature
differential of ±3°F.
17. Take time to understand how to operate and
maintain the heater by using this Owner’s
Manual. Make sure you know how to shut
off the gas supply to the building and also to
the individual heater. Contact your fuel gas
supplier if you have any questions.
18. Any defects found in performing any of the
service or maintenance procedures must
be eliminated and defective parts replaced
immediately. The heater must be retested by
properly quali
fi
ed service personnel before
placing the heater back into use.
Содержание Tradesman CP400
Страница 21: ...Tradesman Construction Heaters Owner s Manual Tradesman 21 FIG 29 FIG 30 COPPER WASHER COPPER WASHER...
Страница 38: ...Tradesman Construction Heaters www lbwhite com Owner s Manual Tradesman 38 Notes...
Страница 39: ......
Страница 78: ...Calefactores Tradesman para construcciones www lbwhite com Manual del usuario Tradesman 38 Notas...
Страница 79: ......
Страница 118: ...Fournaises de construction Tradesman www lbwhite com Manuel du propri taire Tradesman 38 Remarques...
Страница 119: ......