manualshive.com logo in svg
background image

23

Contact your local L.B. White dealer for replacement parts

and service or call L.B. White Co., Inc. at (800) 345-7200 for

assistance.  Be sure that you have your heater model number

and configuration number when calling.

L.B. White Co., Inc. warrants that the component parts of its

heater are free from defects in material and workmanship,

when properly installed, operated, and maintained in

accordance with the Installation and Maintenance

Instructions, safety guides and labels contained with each

unit.  If, within 1

12 m

months ffrom tthe ddate oof ppurchase bby tthe

end  uuser, any component is found to be defective, 

L.B. White Co., Inc. will at its option, repair 

or replace the defective part or heater, with a new part or

heater, F.O.B., Onalaska, Wisconsin.  

A warranty card on file at L.B. White will automatically qualify

a unit and its component parts for warranty consideration.  If

a warranty card is not on file, a copy of the bill of sale will be

required to establish warranty qualification.  If neither is

available, the warranty period will be 12 months from date of

shipment from L B. White.  

Warranty Policy

Replacement Parts and Service

EQUIPMENT

PARTS

L.B. White Co., Inc. warrants that replacement parts

purchased from the company and used on the appropriate L.

B. White heater are free from defects both in material and

workmanship for 12  m

months  ffrom  tthe  ddate  oof  ppurchase  bby

the eend uuser. Warranty is automatic if a component is found

defective within 12 months of the date code marked on the

part.  If the defect occurs more than 12 months later than

the date code but within 12 months from the date of

purchase by the end user, a copy of a bill of sale will be

required to establish warranty qualification. 

The warranty set forth above is the exclusive warranty

provided by L.B. White, and all other warranties, including

any implied warranties or merchantability or fitness for a

particular purpose, are expressly disclaimed.  In the event

any implied warranty is not hereby effectively disclaimed due

to operation of law, such implied warranty is limited in

duration to the duration of the applicable warranty stated

above.  The remedies set forth above are the sole and

exclusive remedies available hereunder.  L.B. White will not

be liable for any incidental or consequential damages

directly or indirectly related to the sale, handling or use of the

heater, and in any event L.B. White's liability in connection

with the heater, including for claims based on negligence or

strict liability, is limited to the purchase price.  

Some states do not allow limitations on how long an implied

warranty lasts, so the above limitation may not apply to you.

Some states do not allow the exclusion or limitation of

incidental or consequential damages, so the above limitation

or exclusion may not apply to you.  This warranty gives you

specific legal rights, and you may also have other rights

which vary from state to state.

Содержание PALS

Страница 1: ...d is listed and approved as a direct gas fired convection construction heater with intended use for primarily the temporary heating of buildings under construction alteration or repair As an alternati...

Страница 2: ......

Страница 3: ...l injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or burns Property damage or...

Страница 4: ...ifications Contact PALS Wilmar Poultry at 1 800 328 8842 or the L B White Co Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has...

Страница 5: ...ES 4 ft BOTTOM 4 ft GAS 6 ft SUPPLY 1 83 m 32 F 16 19 CV250 Propane Natural Vapor Gas M Mo od de el l Ventilation Air Required to Support Combustion CFM Net Weight lbs Shipping Weight lbs Inlet Gas Su...

Страница 6: ...y trained service people must repair the leak check for further leakages and then relight the appliance for you WARNING Do not use this heater for heating human living quarters Do not use in unventila...

Страница 7: ...r 8 Do not block air intakes or discharge outlets of the heater Doing so may cause improper combustion or damage to heater components leading to property damage or animal loss 9 The hose assembly shal...

Страница 8: ...in six feet 6 ft of the heater it serves 10 Check all connections for gas leaks using approved gas leak detectors Gas leak testing is performed as follows Check all pipe connections hose connections f...

Страница 9: ...res must be eliminated and defective parts replaced immediately The heater must be retested by properly qualified service personnel before placing the heater back into use HANGING INSTRUCTIONS A Hangi...

Страница 10: ...f 100 lb cylinders Up to 3 cylinders maximum ASME Tank 500 Gallon 1 000 Gallon This type of regulator installation is typically associated with heaters utilized in a construction application FIG 3 B I...

Страница 11: ...ond trial for ignition If burner flame is not established the igniter will stop sparking and the heater will shut down To recycle the heater for ignition Position On Off switch to Off and then back to...

Страница 12: ...able vapors a and l liquids 3 Regulators can wear out and function improperly Have your gas supplier check the date codes on all regulators installed and check delivery pressures to the appliance to m...

Страница 13: ...Disconnect the electrical leads from the On Off switch 2 Remove the rubber boot from the On Off switch See Fig 6 3 Remove the switch from the control box FIG 6 IGNITION CONTROL VOLTAGE REGULATOR NUT...

Страница 14: ...OR 1 Open access door on barrel 2 Remove retaining pin and side panel from main burner assembly See Fig 12 3 Disconnect flame sensor and ignition leads Remove nuts and screws 4 Remove heat shield and...

Страница 15: ...burner orifice from heater 6 Remove burner orifice from manifold 7 Position the orifice as shown in Fig 11 FIG 11 GAS CONTROL VALVE 1 Remove gas hose from heater 2 Remove control box cover and solenoi...

Страница 16: ...section of this owner s manual 2 Does the pressure reading agree with that given on the dataplate If so no further checking or adjustment is required Proceed to section D 3 If the pressures does not...

Страница 17: ...ied by the flow chart OPERATION SEQUENCE A call for heat occurs from building thermostat 24 Volts D C is sent from building s temperature control to heater s voltage regulator Voltage regulator reduce...

Страница 18: ...pplying 12 Volts D C to Ignition Control Check Switch for Continuity Replace if Defective No 17 Is Fuse in Heater Receiving Proper Voltage Incoming Power Supply Should be 18 30 Volts D C Repair as Nec...

Страница 19: ...ifice Clean Check the Lead for Corroded Terminals Loose Connections Repair or Replace as Necessary No No No Clean the Orifice Yes Is Sensor Reasonably Clean Properly Gapped Clean Sensor with Emery Clo...

Страница 20: ...E BLUE BLACK HIGHVOLTAGE IGNITION LEAD CASE GROUND IGNITOR FLAME SENSOR ELECTRICAL CONNECTION DIAGRAM IF ANY OFTHE ORIGINALWIRES AS SUPPLIEDWITHTHE HEATER MUST BE REPLACED IT MUST BE REPLACEDWITHWIRIN...

Страница 21: ...e Component that houses an electromagnet which is energized by voltage and therefore opens or closes to supply or close off the flow of gas to the burner Gas Hose Flexible connector used to convey gas...

Страница 22: ...cation PARTS SCHEMATIC 24 35 34 22 36 37 33 32 30 27 23 26 25 53 50 41 45 29 28 31 49 43 44 38 51 52 55 54 14 17 48 40 39 18 15 8 10 5 4 56 57 13 11 12 3 6 9 16 20 19 2 46 7 21 47 42 1 29 5 17A 10A 1...

Страница 23: ...ssembly 22641 19 Fuse Holder 21653 20 Cap Fuse 21655 21 Terminal Block 22296 22 Ignition Lead 22651 23 Cord Power 22653 24 Switch Toggle 22714 25 Holder Fuse 22762 26 Fuse 1 5 Amp 250 V 22763 27 Boot...

Страница 24: ...d date o of p purchase b by the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months late...

Отзывы: