NIPPLE
ORIFICE
BURNER
MOUNTING
NUT & WASHER
ELBOW
SOLENOID
VALVE
SOLENOID
COVER
ELBOW
MANIFOLD
BURNER
ORIFICE
BURNER ORIFICE
1. Remove gas hose from control valve inlet.
2. Remove control box and solenoid valve covers. See
Fig. 10.
3. Remove solenoid valve mounting nut and washer.
See Fig. 10.
4. Disconnect solenoid valve leads.
5. Pull solenoid with manifold and burner orifice from
heater.
6. Remove burner orifice from manifold.
7. Position the orifice as shown in Fig. 11.
FIG. 11
GAS CONTROL VALVE
1. Remove gas hose from heater.
2. Remove control box cover and solenoid valve cover.
See Fig. 10.
3. Disconnect solenoid valve leads.
4. Remove solenoid mounting nut. See Fig. 10.
5. Pull solenoid valve with manifold and orifice from
heater. See Fig. 10.
6. Remove elbows and mounting bracket.
ATTENTION
■
The inlet and outlet flow connections are marked on the
replacement gas control’s body. Ensure proper
installation.
FIG. 10