BOOT
SWITCH
ON/OFF SWITCH
IGNITION CONTROL
IGNITION LEAD
FLAME SENSOR
CONNECTION
1. Disconnect all electrical leads from the ignition
control, including igniton cable and flame sensor..
2. Remove the screws securing the ignition control
module to the control box back.
FIG. 7
IGNITION MODULE
12
1. Disconnect the electrical leads from the On/Off switch.
2. Remove the rubber boot from the On/Off switch. See
Fig. 6.
3. Remove the switch from the control box.
FIG. 6
IGNITION
CONTROL
VOLTAGE
REGULATOR
NUT
ATTENTION
■
Handle the voltage regulator at the edges of the board.
Do not touch voltage regulator components. Doing so
may damage the voltage regulator.
1. Disconnect electrical leads from the voltage regulator.
2. Remove nuts which secure voltage regulator to control
box.
FIG. 8
VOLTAGE REGULATOR