Rigging procedures
Rigging procedures
Mounting on a U-bracket
wall-mounting
type of deployment
ceiling-mounting
rigging accessories
X-US1215 or X-UL12
3 x M10 screws
additional material
electric screwdriver
min number of operators
1 or 2
Additional safety for own arrays
When ying an enclosure or an array, use the M8 DIN580 threaded insert to implement a secondary safety.
Ceiling-mounting
Additional holes on the short U-bracket can be used for optimal visual impact.
In this case, the rigging procedure will require 2 operators.
Short U-bracket in horizontal position
In this position, the enclosure applies a diagonal force of
405 daN
on the anchoring points.
Fasteners for wall-mounting or ceiling-mounting
Secure the bracket with three M10 screws.
Select screw length and anchors applicable to the wall or ceiling properties.
The procedure is shown with X-UL12 in horizontal position.
The same procedure applies for X-UL12 in vertical position or in ceiling-mounting conguration and X-US1215 in
horizontal or vertical position or in ceiling-mounting conguration.
Assembly
Procedure
1.
Drive the knobs in the inserts on the enclosure.
Stop when the threading is halfway in.
46
X12 owner's manual (EN) version 1.0
Содержание X12
Страница 1: ...X12 owner s manual EN...
Страница 64: ...Rigging procedures b Finally store the lever on the right 64 X12 owner s manual EN version 1 0...
Страница 66: ...Rigging procedures 6 Lift the assembly 66 X12 owner s manual EN version 1 0...
Страница 80: ...Forbidden con gurations Forbidden con gurations Forbidden Authorized 80 X12 owner s manual EN version 1 0...
Страница 81: ...Forbidden con gurations Forbidden Authorized X12 owner s manual EN version 1 0 81...
Страница 87: ...Speci cations SB18 dimensions 750 mm 29 5 in 707 mm 27 8 in 553 mm 21 8 in X12 owner s manual EN version 1 0 87...
Страница 100: ...L Acoustics 13 rue Levacher Cintrat 91460 Marcoussis France 33 1 69 63 69 63 info l acoustics com www l acoustics com...