ARCS
®
II SYSTEM
rigging manual
VERSION 1.1
ARCSII_RM_EN_1-1
w w w . l - a c o u s t i c s . c o m
8
3
SYSTEM SET-UP
Dismantling an array
Apply the associated set-up procedure in reversed order.
ARCS
®
II
enclosure orientation within the array
Due to the asymmetrical coverage of the ARCS
®
II enclosures, their orientation within an array will determine
the extended coverage direction
.
Horizontal array From behind
Vertical array From behind
Connexion panel Coverage
Connexion panel Coverage
Up 40° up/ 20° down
Left 40° left / 20° right
Down 40° down / 20° up
Right 40° right / 20 ° left
3.1
Ground-stacking
Horizontal
Horizontal stacked on SB28
Assemble the array
Refer to PROCEDURE A
Stack an SB28 array
Assemble the array on top
of the SB28 array
Refer to PROCEDURE A
3.2
Flying
Horizontal
Assemble the array under the motor location
Refer to the PROCEDURE A
Follow-up 1: 2 or 4 ARCS
®
II enclosures
Follow-up 2: 1, 5, 3 or 6 ARCS
®
II enclosures
Install one BUMP3
Refer to PROCEDURE B
Check that all the shackles
are tightened securely
Attach the motor hook to
the BUMP3 shackle
Raise the array
Install two BUMP3
Refer to PROCEDURE B
Install one LIFTBAR
Refer to PROCEDURE C
Check that all the shackles
are tightened securely
Attach the motor hook to
the LIFTBAR shackle
Raise the array
Vertical
Assemble the array under the motor location
Refer to PROCEDURE A
Install the ARCBUMP
Refer to PROCEDURE D
Check that all the shackles are tightened securely
Attach the motor hook to the ARCBUMP shackle(s)
Raise the array
Содержание ARCS II
Страница 1: ...ARCS II rigging manual EN...