Rigging system description
17 holes are available for site angle adjustment. They are compatible with Ø12 mm shackles WLL 1 t (two provided) and
CLAMP250.
A15-LIFT pickup point
Select the same pickup point on each A15-LIFT within an array of up to 6 enclosures.
For larger arrays, refer to
Radial arrays of 7 enclosures and more
(p.95).
Hole 11 serves as a setup point in the radial array procedure (see
Flying a radial array with A15-LIFT
(p.58)).
It is identied by a mark on the label.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
setup point