SKY899
Installation Manual
Page H-4
Appendix H - 009-11900-001
July 18, 2013
Revision F
6.
Press TCAS Mode Key to return to TCAS Test Screen (Figure H-3).
NOTE
Intruding flight patterns are programmed from the TCAS screen and can
be stored in one of sixteen user-named scenario data storage locations.
Eight factory pre-defined scenarios are provided which may be recalled,
modified and stored under a user named scenario.
Figure H-5: TCAS Screen (ATCRBS)
7.
Using the NEXT PARAM and PREV PARAM softkeys to select on-screen functions, set each
parameter as shown in Table H-2.
Table H-2: TCAS Test Screen Parameters
Function
Parameter
SCENERIO
0-Custom
TCAS TYPE
TCAS 1
% REPLY
100
INTRUDER TYPE
ATCRBS
RANGE START
6.00 nm.
RANGE RATE
250 kts.
ALT START
+2000 ft.
CONVERGE
ON
UUT ALT
Local Field
Elevation
The document reference is online, please check the correspondence between the online documentation and the printed version.