Intake/exhaust flue must be placed on the wall that connects to the outside.
y
There should be no dangerous materials or obstructions near intake/exhaust flue.
y
The wall where intake/exhaust flue are placed should be incombustible interior
material.
y
The connection part of the exhaust flue must be airtight by inserting its proper
sealing gasket ; then sufficiently pushing it through. Please check for any exhaust
gas leaks.
y
When the exhaust flue goes through the combustible wall(including the flue), it
should be insulated with over 20mm of incombustible material and keep at least
50mm from any combustible materials.
y
In the exhaust flue or exhaust elbow connection portion, insert its proper sealing
gasket and connect it so that it does not disconnect and allow any exhaust gas
leaks.
y
Cleaning of the Intake/exhaust flue should be done after turning off the boiler and
cooling the pipes.
Cautions for Installation