G O M - 영 문
61
The TOTAL MAXIMUM LENGTH of this configuration is 24.90m
CHOICE OF THE DIAPHRAGM
Flue system length Up to 5.00m
Between
5.00m~12.70m
Between
12.70m~18.30m
Between
18.30m~23.90m
131GOM
–
161GOM
φ
41mm
φ
48mm
φ
52mm
Without
201GOM-251GOM
φ
48mm
φ
52mm
Without
For both these two arguments please follows the instructions contained in the
previous paragraph.
Horizontal separate flue system 80/80mm
–
Type B33
Calculation of the maximum length with the single bends
included in the flue system
Choice of the correct diaphragme with the bends included
in the flue system