2RV/2RW/2RX/2RY/3RA
5-8
Error code
*1: The expiration of the FM certification is also included.
*2: As the normal startup is possible next time, restart automatically and start normally.
*3: Since the normal start-up is not available next time, it is not restarted automatically but moved to the USB
update mode.
*4: The identifier applicable to the code XX is as follows.
Each master file code is "00".
The signature verification result display
6. Unplug the power cord and disconnect the USB memory.
7. Plug in the power cord and turn the power switch (a) on.
8. Check "Processing" is displayed and then turn the power switch (a) off.
Precautions
Never turn the power switch (a) off or disconnect the USB memory (b) during the firmware update.
Safe-Update
When the firmware update was interrupted by power shut-off or disconnecting the USB memory during the
firmware update, the firmware update is retried at the next power-on.
Turn the main power on again while the USB memory is installed.
*: The firmware update that was already completed before power shut-down is skipped.
Code
Error contents
Code
Error contents
0000
Others
S000
Other signature verification error
0100
There is no master file.
S001
The signature verification file is insuffi-
cient.
0200
Master file version discrepancy
N001
Unable to connect the network *2
(There is no target to update.)
03xx *4
There is no download file (No.xx).
04xx *4
File (No.xx) check sum discrepancy
N002
Can not connect to the internet *3
(There is the target to update.)
05xx *4
File (No.xx) preparation failure
06xx *4
File (No.xx) size excess
08xx *4
File (No.xx) writing failure
Update target
Code
Identifier
Controller data
01
BOOT
02
KERNEL
03
FDTBIN
04
ROOTFS
05
APPLI
Optional language data
01
M_OPT_ALL
Engine PWB
01
ENGN
Official signature verification file
Indicate the result
Both certificate and signature files exist and verification is suc-
cessful.
Version number
Both certificate and signature files exist but verification is unsuc-
cessful.
S000
Neither certificate nor signature files exist.
Or either of them does not exist.
S001