2HA/2HB
1-5-12
1-5-3
Optical section
(1) Detaching and refitting the exposure lamp
Take the following procedure when the exposure lamp is to be replaced.
Procedure
1. Remove the original cover or the DP.
2. Remove the two screws holding the upper
right cover and then the cover. Remove the
contact glass.
Figure 1-5-24
3. Move the mirror 1 frame to the cutouts of the
machine.
When moving the mirror 1 frame, do not
touch the exposure lamp nor the inverter
PWB.
4. Detach the exposure lamp connector from
the inverter PWB and release the wire from
three clamps.
Figure 1-5-25
5. Remove the two screws holding the expo-
sure lamp and then the lamp.
6. Replace the exposure lamp and refit all the
removed parts.
Figure 1-5-26
Upper right cover
Contact glass
Clamps
Connector
Inverter PWB
Exposure lamp
Содержание Copystar CS-1635
Страница 1: ...SERVICE MANUAL Published in July 06 2HB70942 Revision 2 CS 2035 CS 1635 ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ......
Страница 14: ...2HA 2HB This page is intentionally left blank ...
Страница 20: ...2HA 2HB 1 1 6 This page is intentionally left blank ...
Страница 126: ...2HA 2HB 1 4 30 This page is intentionally left blank ...
Страница 162: ...2HA 2HB 1 5 36 This page is intentionally left blank ...
Страница 180: ...2HA 2HB 2 1 16 This page is intentionally left blank ...
Страница 210: ...2HA 2HB 2 4 8 ...
Страница 214: ...INSTALLATION GUIDE FOR THE 300 SHEET CASSETTE ...
Страница 221: ...INSTALLATION GUIDE FOR THE DOCUMENT PROCESSOR ...
Страница 232: ...INSTALLATION GUIDE FOR THE DUPLEX UNIT ...
Страница 240: ...INSTALLATION GUIDE FOR THE Printing System X ...
Страница 243: ......
Страница 244: ......