FS-1010
1-5
(4) Power requirements
(5) Environmental requirements
Item
Specification
Item
S
Voltage/current requirement
Watts
220 to 240 V AC
±
10 %, 50/60 Hz
±
2 %/3.8 A
(European countries)
120 V AC
±
10 %, 60 Hz
±
2 %/7.1 A (U.S.A/Canada)
Normal operation: 265 W
Maximum: 818 W
Standby: 13 W
Sleeping: 5 W (220 to 240 V model), 6 W (120 V model)
Item
Specification
Item
S
Operating temperature and
humidity
Maximum altitude
Noise emission (Excluding peaks,
measured at 1 m from printer,
as per ISO7779)
10 to 32.5
°
C (50 to 90.5
°
F), 20 to 80 %RH
2,000 m (6,500 feet)
50 dB (A) maximum/28 dB (A) at standby/unmeasureably low
at sleeping)
Содержание Ecosys FS-1010
Страница 1: ...SERVICE MANUAL Published in Dec 01 Laser printer...
Страница 2: ...Version Replaced pages Remarks Date 1 0 Revision history 5 Dec 2001...
Страница 9: ...Chapter 1 P r o d u c t I n f o r m a t i o n...
Страница 24: ...Chapter 2 Installation Operation...
Страница 40: ...Chapter 3 Maintenance Adjustments...
Страница 52: ...Chapter 4 O p e r a t i o n O v e r v i e w...
Страница 81: ...Chapter 5 D i s a s s e m b l y...
Страница 99: ...FS 1010 5 19 14 Remove the four screws 15 Remove the drive unit Figure 5 2 18 Removing the drive unit...
Страница 101: ...FS 1010 5 21 7 Remove two screws 5 8 Open and split the fuser unit 4 Figure 5 2 20 Splitting the fuser unit 5 5 4...
Страница 111: ...FS 1010 5 31 8 Remove the eraser lamp 9 9 5 2 28 Removing the eraser lamp...
Страница 113: ...Chapter 6 T r o u b l e s h o o t i n g...
Страница 144: ...Appendix A D i a g r a m s...
Страница 153: ...Appendix B S t a t u s P a g e...
Страница 154: ...Appendix B Contents Status page B 3 Printing the service status page B 3 Details of service information B 4...
Страница 160: ...Appendix C I n t e r f a c e...