mTenna Plus and mTenna Select Installation Guide

12.2.2 Align BUC compression points

To align the 1 dB compression points of each BUC, commission each ODU with the network operator. This activity

requires that each ASM can obtain line-of-sight to the satellite, and the installer can contact the NOC for 1 dB

compression measurements while accessing the ASM web-based user interface.

Ensure the ODU remains stationary during each compression test.

1.

Prevent the modem from rebooting by opening telnet into the iDirect Falcon interface and executing the

following command (refer to modem documentation if necessary):

beamselector lock

2.

Obtain P1dB measurement of an ASM.

a.

Navigate the vessel or ASMs so that the ASM under measurement has line-of-sight of the satellite and

achieves PL sync.

b.

Physically cover the ASMs with boxes or other RF-blocking material so that the ASM under measurement

has the best SNR of all ASMs.

If physical blockage of the other ASMs is not possible, you will need to execute more software

commands to force transmit from the desired antenna. See Appendix A for this information.

c.

Confirm that transmit is occurring from the desired ASM using the GUI, or note that the LED for the

desired ASM on the mTenna Select should be green while the others are yellow.

d.

Set RF transmit frequency for the ASM, as given by the NOC, for the ASM by navigating to

Pointing >

Commissioning Mode > Select TX Frequency.

e.

Execute the P1dB testing with the NOC engineer using the iDirect X7 user interface to command transmit

from the modem.

3.

Record the P1dB measurement of each ASM in the following table.

ASM

P1dB measured value

1

2

3

4

4.

Repeat steps 2 and 3 for each ASM.

Содержание mTenna Plus

Страница 1: ...mTennaTM Plus and mTennaTM Select Installation Guide Document number 700 00043 000 rev03 Compatible with ASM software release 1 2 0 3845 25 October 2018...

Страница 2: ...DU 5 4 3 1 Install the rack unit 5 4 3 2 Connect the cables 6 5 Set up mTenna Plus modem side Ethernet 7 6 Adjust ASM software and IP address 8 6 1 Configure a descriptive name for each ASM optional 9...

Страница 3: ...egal information 18 Appendix A Administrative user commands to force transmit during P1dB testing 19 Appendix B Network setup 20 Appendix C mTenna Plus dimensions 21 Appendix D mTenna Select dimension...

Страница 4: ...need to upgrade ASM to software version 1 2 0 3845 for mTenna Plus and mTenna Select to operate correctly Contact Kymeta customer support to get the mTenna Plus and mTenna Select upgrade kit 2 Package...

Страница 5: ...copy client SSH secure shell client and mTenna Plus SSH key 3 1 2 Files required for installation Ensure you have the following files from Kymeta 700 00043 000 mTenna Plus and mTenna Select Installati...

Страница 6: ...abit ethernet switch minimum number of ports is equal to number of ASMs one port for the mTenna Plus one port for administration laptop mTenna Plus 1 unit mTenna Select 1 unit Modem 1 unit Power strip...

Страница 7: ...commends that you label all components of each KyWay ODU This recommendation includes labeling the ODU IDU and cabling from the ASM to its corresponding mTenna I O The following table is a list of cab...

Страница 8: ...000 Kymeta KyWay Terminal Installation Guide 2 Mount the modem 3 Mount the mTenna Plus 4 Mount the mTenna Select 5 Mount the network switch The mTenna Plus and mTenna Select vents are on the top of e...

Страница 9: ...er strip 5 Repeat the above steps for each ASM being installed Install mTenna Plus and mTenna Select cables 1 Connect an Ethernet cable to the modem LAN port on the mTenna Plus and into the administra...

Страница 10: ...with a SSH key unique to the mTenna Plus units On a modem running Velocity software run the following command sudo qdnetconf sh reset On a modem running Evolution software do the following 1 Replace...

Страница 11: ...e and complete a reboot Reboot takes approximately 60 seconds 8 Return to the ASM s web user interface and navigate to Settings Adjust the ASM s reboot time to an appropriate local time and day of the...

Страница 12: ...e name for each ODU to aid in relating the displayed metrics to the physical installation To configure an alias for an ASM do the following 1 connect to the mTenna Plus via SSH 10 0 0 1 username kymet...

Страница 13: ...Tenna Plus Power LED displays green mTenna Plus RX IN LED displays orange mTenna Plus RX OUT LED displays red mTenna Select Power LED displays green mTenna Select TX IN LEDs display red One mTenna Sel...

Страница 14: ...rgument asm1 true asm2 true asm3 true asm4 false Reboot the KyWay IDU for this change to take effect 9 Verify cables After the full system has booted and you have been able to ping and connect to the...

Страница 15: ...ts a failed test Use the following REST API request to obtain the results of the power on self test curl user admin 2Cfg Ant X GET http mTennaPlus_ip v1 mast post where mTennaPlus_ip is the IP address...

Страница 16: ...Example test failure classname OscCtrl max 250025000 message Expected value min actual 246281109 vs 249975000 min 249975000 name Frequency_JESD_RX1_ REC0 status 1 time 0 001 value 246281109 Note that...

Страница 17: ...umentation for the relevant commands A crontab file has five fields for specifying the date and time followed by the command to be run at that interval Modify the first field to change the minute 0 59...

Страница 18: ...ll the ODUs so that each BUC reaches P1dB compression at the same output power by the modem Before beginning P1dB testing on any ASMs ensure that no BUC attenuation is set on any ASM by navigating to...

Страница 19: ...the ASM under measurement has line of sight of the satellite and achieves PL sync b Physically cover the ASMs with boxes or other RF blocking material so that the ASM under measurement has the best SN...

Страница 20: ...rage tmp c Run the script tx_cal py in a Python interpreter with arguments as follows arguments number of ASMs ASM1 p1dB ASM2 p1dB ASM3 p1dB ASM4 p1dB examples python tx_cal py 4 25 24 24 26 python tx...

Страница 21: ...evisions to instructions in sections 7 8 9 and 12 14 Legal information 2018 Kymeta Corporation and its affiliates KYMETA CONNECTED BY KYMETA MTENNA KYWAY K LO image and K LO are trademarks of Kymeta C...

Страница 22: ...ufficient SNR greater than 0 and reasonable scan angle theta 65 3 Force transmit from the desired ASM in the example below this is ASM 1 opt kymeta bin libkymetaservice set setting py s ccp service id...

Страница 23: ...2018 Kymeta Corporation and its affiliates 20 25 October 2018 mTenna Plus and mTenna Select Installation Guide Appendix B Network setup Network and cabling diagram...

Страница 24: ...2018 Kymeta Corporation and its affiliates 21 25 October 2018 mTenna Plus and mTenna Select Installation Guide Appendix C mTenna Plus dimensions...

Страница 25: ...2018 Kymeta Corporation and its affiliates 22 25 October 2018 mTenna Plus and mTenna Select Installation Guide Appendix D mTenna Select dimensions...

Отзывы: