Protects your KwiKool® while in COOL mode from potential damage by delaying the
compressor from starting before the pressures in the mechanical system equalize.
Always activates when your KwiKool cycles off, is turned off, power is lost and then
restored.
Protects your KwiKool® from potential damage to the mechanical system by shutting
down and alerting operators of a condition such as stopped or slowed air flow over
the condenser coil; make up air temperature above operating range or mechanical
failure. Your KwiKool® will sound an audio alarm only and display HP on the control.
To resume operation, the system requires a manual reset after corrective action is
taken, the reset switch is located in the power cord pocket. Push in to reset, if activa-
ted you will hear a click. If this alarm is engaged the system will not operate in cool
fan mode.
Protects your KwiKool® from potential damage to the mechanical system by shutting
down and alerting operators of the condition. This safety activates when pressures
below 20 PSI are detected in the mechanical system of your KwiKool®. Your KwiKool®
will sound an audible alarm and displays LP on the control.
Call 1-800-KWIKOOL if
this alarm is present on start up.
Automatic reset upon correction of low pressure
condition. If this alarm is engaged the system will not operate in cool, fan or heat
mode.
Time Delay
High-Pressure switch and Alarm
Low Pressure switch and Alarm
BUILT IN SAFEGUARDS