During all modes of operation different kinds of error recognition mechanisms are implemented
depending on the operational condition. If an error occurs, the control changes into error mode
(see section Error Processing).
During standard operation the chimney fan is turned off completely if the natural draught is
sufficient. In this case no chimney fan is needed. A motor-driven draught regulator can be
activated additionally in this situation to reduce an excessive natural draught.
If the negative pressure falls below the set value, the chimney fan is switched on again and the
draught regulator is turned off.
Figure 14: Operational modes of Diajekt control