Diajekt Control CFC10
12
Status: 06/18/2014
Figure 8: Terminal layout of pressure sensor
The pressure sensor has to be wired with a screened data line 3 x 0.75 mm².
1.3.2.8 Connection Thermal Element Type K
A rise in temperature can be used as a start signal. For this purpose a thermal element type K
can be installed in the combustion chamber or in the flue gas system as closely as possible to
the combustion chamber. The thermal element is connected with the screw terminals as shown
below.
Figure 9: Terminal layout of thermal element type K