72 | kvm-tec
CAUTION!
Do not use solvent-containing cleansers. Do not use wipes, alcohols (e.g. spiritus) or
chemicals as these could damage the surface.
To clean the product:
• Clean the product with a maintenance product for synthetic material, which is available in
specialized shops.
5. MAINTENANCE AND CARE
Error
Cause
Solution
LED is not
lighting
The devices get no
power
Is the power supply connected? (white box)
LED is lighting
in red
No connection
between Loc and
Rem
Check if the RJ45/network cable is connected well.
(Clicking noise when plugging in)
Control both, if it does not work please send an e-mail to
[email protected]
LED is lighting
in orange
No picture on the
monitor
Check if the local (PC) cable is connected well.
Check if the remote (monitor) cable is connected well.
If everything is connected well but no function appears,
reconnect power supply again.
If the menu is visible, press the
O
key and choose the
resolution of the monitor. Then press the assigned
number on your keyboard.
LED is lighting
green
Screen occurs but
the keyboard is not
working
Plug out/in USB of keyboard and wait until driver is
installed (after few seconds).
Check all USB connections on both sides (Local and
Remote)
If it is still not working, plug out/in DC once more
LED is lighting
green
The screen flickers,
has an incorrect
display
Install current firmware from our homepage www.kvm-
LED is blinking
green
Different firmware
or USB is not
compatible
Please contact the kvm-tec support team via e-mail:
[email protected]
or by phone: +43 2253 81912 30
6. TROUBLESHOOTING
Содержание 6701i
Страница 28: ...28 kvm tec 3 EXTENDER MENU SETTINGS Plug in the USB stick and wait for a moment ...
Страница 29: ...kvm tec 29 3 EXTENDER MENU SETTINGS Wait until all 4 phases have been completed ...
Страница 50: ...50 kvm tec 3 EXTENDER MENU SETTINGS Videosharing ...
Страница 82: ...82 kvm tec 12 15 NOTES ...
Страница 83: ...kvm tec 83 www kvm tec com ...